Specification Of Electrical Parts; Indoor Unit (Ras-10Gkhp-E, Ras-07Gkhp-E); Outdoor Unit (Ras-10Gah-E) - Toshiba RAS-10GKHP-E Service Manual

Split wall type
Table of Contents

Advertisement

4. SPECIFICATION OF ELECTRICAL PARTS

4-1. Indoor Unit (RAS-10GKHP-E, RAS-07GKHP-E)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Micro power module (M01)
4
Microcontroller unit (IC30)
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Bridge rectifier (DB01)
8
Capacitor (C63)
9
Fuse (F01)
10
Varistor (R21, R22)
11
Resistor (R319)
12
Louver motor
13
Relay (Comp., RY01)
14
Relay (Fan, RY03)
15
Relay (Solenoide, RY04)

4-2. Outdoor Unit (RAS-10GAH-E)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Overload relay
5
Type
MMF-240-20-4B
m
RM1260V
TMP87CM40AFG-6G61
LC*SS11V-06270
D3SBA60
EKMH401VSN470MP20S 47mF, 400 V
BET6.3A
TND15G-561KB0SLAA0
RF-2TK5R6
MP24ZT
G4A-1A-E
G5NB-1A
G5NB-1A
Type
Output (Rated) 1000 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
PH180X1C-4DZDN3 Winding resistance ( )
(at 20 C)
Output (Rated) 20 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
Winding resistance ( )
SKF-240-20B
(at 20°C
DS451155NPQB AC 450 V ~, 1.5mF
RS44B256U0213S AC 440 V ~, 25mF
JMRA99208-9102 U/T : 4.2A (80° C), OPEN : 135±5°C, CLOSE : 69±11°C
- 12 -
FILE NO. SVM-06037
Specifications
AC Motor with 135 °C thermo fuse
°
W
10k at 25 C
°
W
10k at 25 C
27mH, 600mA
4A, 600 V
6.3A, 250VAC
560 V
W
5.6
, 2 W
12VDC
Rating 20A/AC250 V, 12VDC
Rating 3A/AC250 V, 12VDC
Rating 3A/AC250 V, 12VDC
Specifications
W
°
W
C-R
C-S
3.33
3.78
Red-Black
White-Black
235.2
260.1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents