Hitachi DZ-GX20A Service Manual page 55

Dvd video camera/recorder
Hide thumbs Also See for DZ-GX20A:
Table of Contents

Advertisement

Troubleshooting > Trouble Diagnosis
Camera recorded image is abnormal
Remove the MAN circuit
board and solder a lead
wire to check points
Set to service position (A).
Yes
Is camera recorded
image output?
No
Yes
TL2002 (RG),
No
TL2004 (H2),
TL2005 (H1):
Pulses
Yes
TL2009 (V3), TL2010 (V4),
No
TL2012 (V2), TL2013 (V1):
Pulses
Yes
Replace IC1001
(CCD image sensor).
List of check points
Circuit board
Symptom
(side)
TL0523
MAN (A)
TL0525
MAN (A)
TL2001
MAN (B)
TL2002
MAN (A)
TL2004
MAN (A)
TL2005
MAN (A)
TL2009
MAN (A)
TL2010
MAN (A)
TL2012
MAN (A)
TL2013
MAN (A)
IC0502-26
MAN (B)
Yes
TL2001 (CCD_OUT1):
CCD output signal?
No
*1: 12 V DC for DZ-GX20A; 15 V DC for other models.
No
TL0523 (C15/12V):
( *1)
12V or 15V DC
Replace IC2001.
Replace IC2004.
V1 & V3 pulses
V2 & V4 pulses
15
0
-7
4 - 30
Lead wire
Location on
soldered
circuit board
or not
3B
Need
1B
Need
4C
Need not
3B
Need
3B
Need
3B
Need
3C
Need
3B
Need
3C
Need
3B
Need
5E
Need not
Replace the MAN
circuit board.
TL0525 (C8.5V):
8.5V DC
Yes
Replace D0508 or
(*2)
D0509.
*2: Replace D0508 for DZ-GX20A; D0509 for other models.
H1 & H2 pulses
3.3
0
0
-7
Replace IC0502.
No
No
IC0502-26: 7V DC
Yes
Replace Q0511.
RG pulse
13.3
10.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dz-mv780aDz-mv730a

Table of Contents