Diagnostic Error Code
011-197-XXX
Serial port test warning
011-198-XXX
Serial port test aborted
011-199-XXX
Serial port test failed, cause unknown
011-2XX-XXX
Serial port signal failure
014-000-XXX
Parallel port Interface Test Passed
014-001-XXX
Parallel port Presence
014-002-XXX
014-003-XXX
Parallel port Timeout/Parity error
014-013-XXX
014-014-XXX
Parallel port Control Signal/Loopback test
failure
014-015-XXX
Parallel port External Loopback failure
014-027-XXX
Parallel port Configuration/Setup error
014-03X-XXX
014-04X-XXX
Parallel port failure
014-195-XXX
Parallel port Test aborted by user
014-196-XXX
Parallel port test halt, error threshold exceeded
014-197-XXX
Parallel port test warning
FRU/Action
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
1.
If a component is called out, make sure it
is connected and/or enabled
2.
Flash the system and re-test
3.
Go to the "Undetermined problems"
section
1.
Go to the "Undetermined problems"
section
2.
Flash the system and re-test
3.
Replace component under function test
1.
External serial device
2.
System board
1.
No action
1.
Remove external parallel device, if
present
2.
Run setup, enable port
3.
System board
1.
System board
1.
System board
1.
Wrap plug
2.
System board
1.
Run Setup, enable port
2.
Flash the system
3.
System board
1.
System board
1.
Information
2.
Re-start the test, if necessary
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test