Diagnostic Error Code
005-025-XXX
Video Checksum Value error
005-027-XXX
Video Configuration/Setup error
005-031-XXX
Video Device Cable failure
005-032-XXX
Video Device Controller failure
005-036-XXX
Video Register error
005-038-XXX
System BIOS extension failure
005-040-XXX
Video IRQ failure
005-195-XXX
Video Test aborted by user
005-196-XXX
Video test halt, error threshold exceeded
005-197-XXX
Video test warning
005-198-XXX
Video test aborted
005-199-XXX
Video test failed, cause unknown
005-2XX-XXX
005-3XX-XXX
Video subsystem error
006-000-XXX
Diskette interface Test Passed
006-0XX-XXX
Diskette interface error
FRU/Action
1.
Video card, if installed
2.
System board
1.
Run Setup
2.
Video drivers update
3.
Video card, if installed
4.
System board
1.
Video cable
2.
Monitor
3.
Video card, if installed
4.
System board
1.
Video card, if installed
2.
System board
1.
Video card, if installed
2.
System board
1.
Video card, if installed
2.
System board
1.
Video card, if installed
2.
System board
1.
Information
2.
Re-start the test, if necessary
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
1.
If a component is called out, make sure it
is connected and/or enabled
2.
Flash the system and re-test
3.
Go to the "Undetermined problems"
section
1.
Go to the "Undetermined problems"
section
2.
Flash the system and re-test
3.
Replace component under function test
1.
Video card, if installed
2.
System board
1.
No action
1.
Diskette drive Cable
2.
Diskette drive
3.
System board
Chapter 6. Symptom-to-FRU Index