8. This completes the installation of the air conditioner.
We recommend that power be supplied to the air
conditioner and check for proper operation. See
section "J. Configuration Of Remote" and refer to
Operating Manual or User's Guide for a description
of the air conditioner operation.
J. CONFIGURATION OF REMOTE
The Hand Held Remote when shipped from Dometic is al-
ways programmed as a cool/furnace model. The dip switches
are located in the hand held remote battery compartment.
See FIG. 33. If the control is to be used with the electric
heat strip or without the furnace its configuration must be
changed as follows:
FIG. 33
BATTERY COMPARTMENT
Dip Switches
"ON"
Dip Switches
"OFF"
UNIT FIELD WIRING DIAGRAM
RUN CAP
1. Cool/furnace operation: Dip switches 1,2,& 3 "ON"
- dip switch 4 "OFF".
2. Cool Only-no heat operation: Dip switch 1 & 3 "ON"
- dip switches 2 & 4 "OFF".
3. Cool/Heat operation: Dip switches 1,2,3, & 4 "ON"
-no dip switches "OFF".
Note: After the remote switches are changed, point remote
at the receiver and press the reset button.
6 PIN CONN
NOT USED ON
SOME MODELS