Test Equipment - Motorola CDM Series Basic Service Manual

Cdm series professional series two-way mobile radio
Hide thumbs Also See for CDM Series:
Table of Contents

Advertisement

2-20

2.14 Test Equipment

Table 2-2 lists test equipment required to service these and other two-way radios.
NOTE
While all of these items are available from Motorola, most are standard shop
equipment items, and any equivalent item capable of the same performance may
be substituted for the item listed.
Motorola Part No.
R2000, R2600
Service Monitor
R2400, or R2001
with trunking
option for Pri-
vacy Plus™ and
Smartnet Sys-
tems™
*R1049
Digital Multimeter
*S1100
Audio Oscillator
*S1053,
AC Voltmeter,
*SKN6009,
Power Cable
*SKN6001
for meter,
Test leads for meter
R1053
Dual-trace Oscillo-
scope
R1443A
Broadband Watt-
meter
S1339
RF Millivolt Meter
*R1013
SINAD Meter
S1348 (prog)
DC Power Supply
For those customers that need to test the LTR functioning of their radio instead of the R2600,
purchase the HP8920 with LTR option. Please see your local Hewlett Packard representative for
this item.
Table 2-2: Recommended Test Equipment
Description
This monitor will
substitute for items
listed below with an
asterisk *
67 to 200Hz tones
• 1 mV to 300 V
• 10 MΩ input imped-
ance
20 MHz bandwidth,
5 mV/cm - 20 V/cm
100 µV to 3 VRF, 10
kHz to 1.2 GHz
0-20 Vdc, 0-20 Amps
Characteristics
Application
Frequency/deviation meter and sig-
nal generator for wide-range trouble-
shooting and alignment
Two meters recommended for AC/
DC voltage and current measure-
ments
Used with service monitor for injec-
tion of PL tones
Audio voltage measurements
Waveform measurements
Transmitter power output measure-
ments
RF level measurements
Receiver sensitivity measurements
Bench supply for 13.2Vdc
Service Aids

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdm1250Cdm1550 lsCdm1550 ls plusCdm750Cdm1550-ls+