Flue/Chimney Trim; Terminal Guard; Flue/Chimney Deflector; Flue/Chimney Accessories - Baxi MainEco Heat 15 Installation And Service Manual

Gas fired wall mounted powered flue condensing boiler
Hide thumbs Also See for MainEco Heat 15:
Table of Contents

Advertisement

Fig. 15
Fig. 16
7215845 - 01 (08/14)
5.3.9
1. The flexible flue trims supplied can be fitted on the outer and
inner faces of the wall of installation (Fig. 14).
Terminal
5.3.10
Guard
1. When codes of practice dictate the use of terminal guards
(Fig. 15) 'Multifit' accessory part no. 720627901 can be used
(NOTE: This is not compatible with Flue Deflector referred too
below).
2. There must be a clearance of at least 50mm between any
part of the terminal and the guard.
3. When ordering a terminal guard, quote the appliance name
and model number.
4. The flue terminal guard should be positioned centrally over
the terminal and fixed as illustrated.
Flue Deflector
5.3.11
1. Push the flue deflector over the terminal end, it may point
upwards as shown, or up to 45° either way from vertical. Secure
the deflector to the terminal with screws provided (Fig. 16).
5.3.12
clamps etc.) refer to the Flue Accessories & Fitting Guide
supplied in the literature pack.

Flue/Chimney Trim

Terminal Guard

Flue/Chimney Deflector

Flue/Chimney Accessories

For full details of Flue Accessories (elbows, extensions,
WARNING
SUPPORT - All flue systems MUST be securely
supported, a MINIMUM of once every metre and at
each change of direction. It is recommended that
every straight piece is supported irrespective of
length. Additional supports are available as
accessories.
VOIDS - Consideration must be given to flue systems
in voids and the provision of adequate access for
subsequent periodic visual inspection.