Flue/Chimney Location - Baxi MainEco Heat 15 Installation And Service Manual

Gas fired wall mounted powered flue condensing boiler
Hide thumbs Also See for MainEco Heat 15:
Table of Contents

Advertisement

5
Before Installation
R
I
F
L
Likely flue positions requiring
a flue terminal guard
Terminal Position with Minimum Distance (Fig. 11)
1
A
Directly below an opening, air brick, opening windows, etc.
B
1
Above an opening, air brick, opening window etc.
C
1
Horizontally to an opening, air brick, opening window etc.
2
D
Below gutters, soil pipes or drain pipes.
2
E
Below eaves.
2
F
Below balconies or car port roof.
2
G
From a vertical drain pipe or soil pipe.
H
2
From an internal or external corner.
I
Above ground, roof or balcony level.
J
From a surface or boundary line facing a terminal.
K From a terminal facing a terminal (Horizontal flue).
From a terminal facing a terminal (Vertical flue).
L From an opening in carport (e.g. door, window)
into the dwelling.
M Vertically from a terminal on the same wall.
N Horizontally from a terminal on the same wall.
R From adjacent wall to flue (vertical only).
S From an adjacent opening window (vertical only).
T Adjacent to windows or openings on pitched and flat roofs
U Below windows or openings on pitched roofs
30
MainEco Heat
T
J,K
N
M
I
B
A
G
I
5.3.7

Flue/Chimney Location

1. The following guidelines indicate the general requirements for
siting balanced flue terminals. For GB recommendations are
given in BS 5440 Pt 1. For IE recommendations are given in the
current edition of I.S. 813 "Domestic Gas Installations".
Under car ports we recommend the use of the plume
displacement kit.
The terminal position must ensure the safe and
nuisance - free dispersal of combustion products.
U
D
A
C
E
I
I
S
J,K
F
A
H
H
Fig. 11
(mm)
300
300
300
25 (75)
25 (200)
25 (200)
25 (150)
25 (300)
300
1
In addition, the terminal should be no nearer than
600
150 mm to an opening in the building fabric formed
1200
for the purpose of accommodating a built-in element
600
such as a window frame.
1200
2
Only ONE 25mm clearance is allowed per
1500
installation. If one of the dimensions D, E, F, G or H
300
is 25mm then the remainder MUST be as shown in
300
brackets, in accordance with B.S.5440-1.
1000
600
2000
7215845 - 01 (08/14)