Warning
SUPPORT - All flue systems MUST be securely supported at a
MINIMUM of once every metre & every change of direction. It is
recommended that every straight piece is supported irrespective
of length. Additional supports are available as accessories.
VOIDS - Consideration must be given to flue systems in voids and
the provision of adequate access for subsequent periodic visual
inspection.
5.4.8

Flue/chimney trim

The flexible flue trims supplied can be fitted on the outer and inner faces of
the wall of installation.
PN-0000390
5.4.9
Terminal guard
When codes of practice dictate the use of terminal guards Multifit accesso­
ry part no. 720627901 can be used
Important
This guard is not compatible with Flue Deflector referred to below.
There must be a clearance of at least 50 mm between any part of the
terminal and the guard.
When ordering a terminal guard, quote the appliance name and model
number.
PN-0000460
The flue terminal guard should be positioned centrally over the terminal
and fixed as illustrated.
5.4.10

Flue/chimney deflector

1
Flue deflector
Push the flue deflector over the terminal end. It may point upwards as
shown, or up to 45° either way from vertical. Secure the deflector to the
terminal with screws provided.
PN-0000461
5.4.11

Flue/chimney accessories

See
For full details of Flue Accessories (elbows, extensions, clamps
etc.) refer to the Flue Installation Guide supplied in the literature
pack.