Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
York Manuals
Heat Pump
ZJ Series
Technical manual
With Powered Convenience Outlet - York ZJ Series Technical Manual
Xp series is heat pump zj is cooling only or electric cooling/gas heating 3-5 ton 60 hertz, r-410a
Hide thumbs
Also See for ZJ Series
:
Instruction manual
(66 pages)
,
Installation manual
(74 pages)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
Table Of Contents
79
page
of
79
Go
/
79
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
251933-YTG-B-0806
With Powered Convenience Outlet
ZJ036-060
Compressors
Size
(each)
Volt
(Tons)
RLA LRA
MCC
208-1-60 16.6
88.0
26.0
230-1-60 16.6
88.0
26.0
208-3-60 12.8
95.0
20.0
036
(3.0)
230-3-60 12.8
95.0
20.0
460-3-60 6.4
45.0
10.0
575-3-60 5.4
38.0
8.5
208-1-60 21.1 113.0 33.0
230-1-60 21.1 113.0 33.0
208-3-60 16.0 120.0 25.0
048
(4.0)
230-3-60 16.0 120.0 25.0
460-3-60 8.3
60.0
13.0
575-3-60 6.7
40.0
10.5
Unitary Products Group
http://www.rezine.net
OD Fan
Supply
Pwr
Motors
Blower
Conv
Electric Heat Option
(each)
Motor
Outlet
FLA
FLA
FLA
Model
None
E05
E07
2.3
7.6
10.0
E10
E15
E20
None
E05
E07
2.3
7.6
10.0
E10
E15
E20
None
E05
E07
2.3
5.2
10.0
E10
E15
E20
None
E05
E07
2.3
5.2
10.0
E10
E15
E20
None
E07
1.3
2.6
5.0
E10
E15
E20
None
E10
1.3
2.0
4.0
E15
E20
None
E05
E07
2.3
7.6
10.0
E10
E15
E20
None
E05
E07
2.3
7.6
10.0
E10
E15
E20
None
E05
E07
2.3
5.2
10.0
E10
E15
E20
None
E05
E07
2.3
5.2
10.0
E10
E15
E20
None
E07
1.3
2.6
5.0
E10
E15
E20
None
E10
1.3
2.0
4.0
E15
E20
Page 49
Max Fuse
1
MCA
Breaker
(Amps)
Size
(Amps)
kW
Amps
--
--
40.7
50
4.0
19
46.0
50
5.6
27
55.7
60
8.0
38
70.1
80
11.9
57
93.5
100
15.9
76
117.6
125
--
--
40.7
50
5.3
22
49.6
50
7.5
31
61.1
70
10.6
44
77.2
80
15.9
66
104.8
110
21.2
88
132.4
150
--
--
33.5
45
4.0
11
33.5
45
5.6
16
38.4
45
8.0
22
46.8
50
11.9
33
60.3
70
15.9
44
74.2
80
--
--
33.5
45
5.3
13
34.9
45
7.5
18
41.6
45
10.6
25
50.9
60
15.9
38
66.8
70
21.2
51
82.7
90
--
--
16.9
20
6.8
8
19.7
20
10.1
12
24.7
25
13.6
16
29.9
30
19.5
23
38.8
40
--
--
13.8
15
10.6
10
20.2
25
15.9
15
26.6
30
21.2
20
33.0
35
--
--
46.3
60
4.0
19
46.3
60
5.6
27
55.7
60
8.0
38
70.1
80
11.9
57
93.5
100
15.9
76
117.6
125
--
--
46.3
60
5.3
22
49.6
60
7.5
31
61.1
70
10.6
44
77.2
80
15.9
66
104.8
110
21.2
88
132.4
150
--
--
37.5
45
4.0
11
37.5
45
5.6
16
38.4
45
8.0
22
46.8
50
11.9
33
60.3
70
15.9
44
74.2
80
--
--
37.5
45
5.3
13
37.5
45
7.5
18
41.6
50
10.6
25
50.9
60
15.9
38
66.8
70
21.2
51
82.7
90
--
--
19.3
25
6.8
8
19.7
25
10.1
12
24.7
25
13.6
16
29.9
30
19.5
23
38.8
40
--
--
15.4
20
10.6
10
20.2
25
15.9
15
26.6
30
21.2
20
33.0
35
2
/
3
47
Table of
Contents
Previous
Page
Next
Page
1
...
46
47
48
49
50
51
52
53
Show Quick Links
Quick Links:
Description
Technical Guide
Nomenclature
Physical Data
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Related Manuals for York ZJ Series
Industrial Equipment York ZJ150 Installation Manual
(74 pages)
Air Conditioner York ZJ037-061 Instruction Manual
(66 pages)
Air Conditioner York ZR Series Wiring Diagrams
R-410a, 3 - 6 ton, 60 hertz (95 pages)
Air Conditioner York XP036 Technical Manual
R-410a zf / zr / xp series 3 - 5 ton 60 hertz (73 pages)
Heat Pump York H3CE180 User Manual
Split system air-cooled condensing unit (12 pages)
Heat Pump York E1RA Series Installation Instruction
Outdoor split-system heat pumps 10, 12, 14 seer (13 pages)
Heat Pump York YCUL0020 Installation, Operation And Maintenance Manual
Air-cooled scroll compressor condensing units style e (178 pages)
Heat Pump York Affinity BHZ024 Technical Manual
Affinity series 2 - 5 ton 60 hertz heat pump (37 pages)
Heat Pump York STELLAR 2000 EFD Series Technical Manual
Split-system heat pumps (24 pages)
Heat Pump York TH4 Series Installation Manual
R-410a outdoor split-system heat pump (24 pages)
Heat Pump York LX Series Technical Manual
Split system heat pumps (192 pages)
Heat Pump York 036-048 Technical Manual
Split-system heat pumps 10 seer – r-22 (17 pages)
Heat Pump York B1HA018A06 Installation Instruction
Champion series single package heat pumps (25 pages)
Heat Pump York F*FP Technical Manual
Single piece air handlers for use with split-system cooling & heat pumps (16 pages)
Heat Pump York E1FB180 Installation Instructions Manual
Split-system heat pumps outdoor units (20 pages)
Heat Pump York B1HH018 Installation Instructions Manual
Champion series single package heat pumps (28 pages)
Related Content for York ZJ Series
SUNLINE 2000 Electrical Data -With Powered Convenience Outlet
York SUNLINE 2000
BP 180 Electrical Data -With Powered Convenience Outlet
York BP 180
BQ240 Electrical Data -With Powered Convenience Outlet
York BQ240
SUNLINE 2000 BP 072 Bp 072 Electrical Data Belt Drive With Powered Convenience Outlet
York SUNLINE 2000 BP 072
SUNLINE 2000 Electrical Data -Without Powered Convenience Outlet
York SUNLINE 2000
Predator BP078 Electrical Data Bp078 (6-1/2 Ton) Hp With Pwrd Convenience Outlet
York Predator BP078
sunline 2000 Electrical Data - Bp036-072 Direct Drive W/O Powered Convenience Outlet
York sunline 2000
Sunline 2000 BQ 036 Electrical Data - Bq036-060 Direct Drive W/O Powered Convenience Outlet
York Sunline 2000 BQ 036
BQ 036 Electrical Data - Bq036 & 048 Direct Drive With Powr'd Convenience Outlet
York BQ 036
BP 036 Pg. # 23 Electrical Data - Bp036-072 Direct Drive W/ Powered Convenience Outlet
York BP 036
YJ-40 Typical Field Wiring Diagram Nj-30/-40 Evaporator Units, Nj- 50 Air Handler And Macz-50A Evaporator Coil When Matched With Yj-30/-40/-50 Condenser
York YJ-40
TH4 Series Test Input Functionality With Y
York TH4 Series
YHE Series Test Input Functionality With Y
York YHE Series
SUNLINE 2000 BCH 036 Power Exhaust Damper Setpoint (With Or Without Power Exhaust)
York SUNLINE 2000 BCH 036
LX Series System Capacity - With High Efficiency Motor Furnaces
York LX Series
LX Series System Capacity - With High Efficiency Motor Furnaces
York LX Series
This manual is also suitable for:
Xp series
Zj036
Zj048
Zj060
Xp036
Xp048
...
Show all
Xp060
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL