DESCRIPTION
This fan coil unit provides the flexibility for installation in any
upflow or horizontal application. These versatile models may
be used for split-system cooling or heat pump operation.
Compact cabinets along with return air options in both the
upflow and horizontal positions allow this unit to fit into tight
spaces such as attics, crawl spaces, and closets.
NOTE: For matching condensing units and performance
data, refer to condenser technical guides.
FEATURES
CABINET -The compact and sturdy cabinet is protected with
a durable, attractive finish to prevent rust. The cabinet is also
insulated to prevent cabinet sweating. F*FP and F*FV mod-
els have 3/4 inch insulation.
BLOWERS - Blowers are sized to circulate air both quietly
and efficiently. The direct-drive, multi-speed motors provide a
selection of air volume to match any application. Motor
speeds may be selected via quick connect terminal at the
motor. Slide-out blower/motor assemblies provide for easy
servicing.
COILS - Using the latest in heat transfer technology, the rifled
tube coil/aluminum fin coils produce high performance ratings
and provide long lasting quality. The coils are capable of bot-
tom return air in the upflow position, and right or left end
return air in the horizontal position.
FACTORY INSTALLED TXV - Air handler models F*FP and
F*FV have factory installed TXV metering device.
ELECTRIC HEATERS - Models providing up to 25kw of heat
are available as field installed accessories. Electric heaters
are available in both single and three phase.
EASY INSTALLATION - These fan coil units are designed to
provide the lowest total installation cost. Accessible color
coded control wiring, top and side power wiring knockouts,
easy to install drain connections and electric heaters all com-
bine to minimize installed cost on every job.
CONTROL BOARD - The control board is equipped with low
voltage terminal strips for easy installation. The control board
is also equipped with plug-in receptacles for the auxiliary
heaters.
ISO 9001
Certified Quality
Management System
295421-YTG-B-0707

Advertisement

Table of Contents
loading

Summary of Contents for York F*FP

  • Page 1 CABINET -The compact and sturdy cabinet is protected with a durable, attractive finish to prevent rust. The cabinet is also insulated to prevent cabinet sweating. F*FP and F*FV mod- els have 3/4 inch insulation. BLOWERS - Blowers are sized to circulate air both quietly and efficiently.
  • Page 2 DIMENSIONS SHIPPING BRACKET* REMOVE PRIOR TO INSTALLATION (2 SCREWS) 10-3/8 DRAIN CONNECTIONS FOR HORIZONTAL APPLICATIONS VAPOR OPENING LIQUID OPENING DRAIN CONNECTIONS FOR UPFLOW APPLICATIONS Model Height F4FP024H06T2* 40-3/4 F4FP030H06T2* 40-3/4 F4FP036H06T2* 40-3/4 F4FP040H06T2* 40-3/4 F4FP042H06T2* 40-3/4 F4FP045H06T2* 50-3/4 F5FP048H06T2* 50-3/4 F5FP060H06T2* 50-3/4 F4FV060H06T2*...
  • Page 3: Cooling Capacity

    295421-YTG-B-0707 COIL TECHNICAL DATA Models Application F4FP024H06T2A A/C & HP F4FP024H06T2B A/C & HP F4FP030H06T2A A/C & HP F4FP036H06T2A A/C & HP F4FP040H06T2A A/C & HP F4FP040H06T2C A/C & HP F4FP042H06T2A A/C & HP F4FP042H06T2C A/C & HP F4FP045H06T2C A/C & HP F5FP048H06T2C A/C &...
  • Page 4 0.50” W.C. Maximum allowable external static pressure may also be limited by minimum CFM requirements for proper Heat Pump operation. 1. Includes Return Air Filter and Largest Electric Heater. All F*FP series air handler units are UL Listed up to 0.50" w.c. external static pressure, including air filter, wet coil, and largest KW size heater. LIMITATIONS These units must be wired and installed in accordance with all national and local safety codes.
  • Page 5 1. Includes Return Air Filter and Largest Electric Heater. All F*FP series air handler units are UL Listed up to 0.50" w.c. external static pressure, including air filter, wet coil, and largest KW size heater. APPLICATION FACTORS-RELATED CFM VS. ACTUAL CFM...
  • Page 6: Delay Profile

    EXTENDED AIR FLOW DATA - F4FV VARIABLE SPEED MODELS CFM/TAP SELECTION - F4FV High Speed Cooling and Model Jumper F4FV060H06T2* "COOL” TAP 2100 “A” 1980 "B” 1860 "A” 1750 "B” 1675 "A” 1605 "C” 1575 "B” 1510 "D” 1420 "C” 1335 "D”...
  • Page 7: Electrical Data - Cooling Only

    295421-YTG-B-0707 Physical and Electrical Data MODEL Blower - Diameter Width Motor Nominal RPM Voltage Full Load AMPS Locked Rotor Type Size Filter Permanent Type Kit Shipping/Operating Weight (lbs.) MODEL Blower - Diameter x Width Motor Nominal RPM Voltage Full Load Amps Locked Rotor Type...
  • Page 8: Kw & Mbh Conversions - For Total Power Input Requirement

    ELECTRICAL DATA - 1∅ - 208/230 - 1-60 Heater Models Model 2HK*6500506B F4FP024H06T2* 2HK*6500806B 2HK*6501006B 2HK*6500506B 2HK*6500806B F4FP030H06T2* 2HK*6501006B 2HK16501506B 2HK*6500506B 2HK*6500806B 2HK*6501006B F4FP036H06T2* 2HK16501506B 2HK16501906B 2HK*6500506B 2HK*6500806B F4FP040H06T2* 2HK*6501006B 2HK16501506B 2HK*6500506B 2HK*6500806B F4FP042H06T2* 2HK*6501006B 2HK16501506B 2HK*6500506B 2HK*6500806B F4FP045H06T2* 2HK*6501006B 2HK16501506B 2HK16500506B 2HK16500806B...
  • Page 9 295421-YTG-B-0707 ELECTRICAL DATA - 1∅ (SINGLE SOURCE POWER SUPPLY) - COPPER WIRE Models 2HK*6500506B F4FP024H06T2* 2HK*6500806B 2HK*6501006B 2HK*6500506B 2HK*6500806B F4FP030H06T2* 2HK*6501006B 2HK16501506B 2HK*6500506B 2HK*6500806B 2HK*6501006B F4FP036H06T2* 2HK16501506B 2HK16501906B 2HK*6500506B 2HK*6500806B F4FP040H06T2* 2HK*6501006B 2HK16501506B 2HK*6500506B 2HK*6500806B F4FP042H06T2* 2HK*6501006B 2HK16501506B 2HK*6500506B 2HK*6500806B F4FP045H06T2* 2HK*6501006B 2HK16501506B...
  • Page 10 ELECTRICAL DATA - 1 Ø (MULTI-SOURCE POWER SUPPLY) - COPPER WIRE Models Heater Model F4FP030H06T2* 2HK16501506B 25.8/28.7 45.1/52.1 2HK16501506B 26.8/29.5 45.1/52.1 F4FP036H06T2* 2HK16501906B F4FP040H06T2* 2HK16501506B 25.8/28.7 45.1/52.1 F4FP042H06T2* 2HK16501506B 28.1/30.5 45.1/52.1 F4FP045H06T2* 2HK16501506B 26.6/29.3 45.1/52.1 2HK16501506B 32.8/35.6 45.1/52.1 F5FP048H06T2* 2HK16502006B 55.3/61.6 45.1/52.1 2HK16502506B 32.8/35.6 45.1/52.1 45.1/52.1 2HK16501506B 32.8/35.6 45.1/52.1 F5FP060H06T2*...
  • Page 11 295421-YTG-B-0707 ELECTRICAL DATA - 3∅ - (SINGLE SOURCE POWERSUPPLY) - COPPER WIRE Models F4FP024H06T2* 2HK06501025B 2HK06501025B F4FP030H06T2* 2HK06501525B 2HK06501025B F4FP036H06T2* 2HK06501525B 2HK06501025B F4FP040H06T2* 2HK06501525B 2HK06501025B F4FP042H06T2* 2HK06501525B 2HK06501025B F4FP045H06T2* 2HK06501525B 2HK06501025B F5FP048H06T2* 2HK06501525B 2HK06501025B F5FP060H06T2* 2HK06501525B 2HK06501025B F4FV060H06T2* 2HK06501525B 1. O.C.P. = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse. FIELD WIRING CONNECTION - COOLING ONLY THERMOSTAT COIL...
  • Page 12 FIELD WIRING CONNECTIONS - COOLING MODELS WITH ELECTRIC HEAT WIRING F* SERIES Air Handler Control Wiring Typical A/C - Cooling only Applications AIR HANDLER THERMOSTAT BOARD CFM selection board only on F4FV model FIELD WIRING CONNECTIONS - SINGLE STAGE HEAT PUMP THERMOSTAT CFM selection board only on F4FV model...
  • Page 13: Typical Installation

    295421-YTG-B-0707 TYPICAL INSTALLATION POWER WIRING TO MAIN POWER SOURCE REFRIGERANT LINES CONDENSATE DRAIN TYPICAL APPLICATIONS UPFLOW Unitary Products Group SUPPLY POWER WIRING ELECTRIC HOT WATER HEATER (Must comply with water heater installation instructions) ORIZONTAL RIGHT HAND APPLICATION LEFT HAND APPLICATION CONTROL WIRING THERMOSTAT...
  • Page 14 295421-YTG-B-0707 NOTES Unitary Products Group...
  • Page 15 295421-YTG-B-0707 NOTES Unitary Products Group...
  • Page 16 Subject to change without notice. Printed in U.S.A. Copyright © by York International Corp. 2007. All rights reserved. Unitary Products Group NOTES 5005 York Drive 295421-YTG-B-0707 Supersedes: 295421-YTG-A-0507 Norman 73069...

Table of Contents