The NetScreen-5000 Series device allows you to configure the chassis alarm, an audible
warning that sounds when a system failure or hazardous event occurs. To determine
which failures and events trigger the chassis alarm:
1.
Configure the audible alarms by executing the following command:
set chassis audible-alarm string
where string can be any of the following keywords:
all
battery
fan-failed
power-failed
temperature
2.
After configuring the alarm, it is advisable to view alarm environment
information by executing the following command:
get chassis
NetScreen-5000 Series
/16, enter the following:
C
A
HASSIS
LARM
Enables all chassis alarms.
Sets the chassis alarm to sound when a battery fails.
Sets the chassis alarm to sound when a fan fails.
Sets the chassis alarm to sound when a power supply fails.
Sets the chassis alarm to sound when the temperature goes outside of
the acceptable range.

Configuring the Chassis Alarm

31