Replacement routines
Ê Press the two hooks on the bottom side downward and pull out the plastic
front cover frontward.
4.2

Replacing the operating panel module

Ê Open the server and remove the front cover / rack front cover as described
in the section "Preparation" on page 13.
Figure 2: Removing the operating panel module
Ê Press the two metal tongues of the EasyClick rails inward (1) until the locking
mechanism is released.
Ê Pull the operating panel module forward out of its mounting location (2) until
you can remove the ribbon cable and the USB cable from the operating
panel board. Remove the two cables.
Ê Pull the operating panel module out of its bay as far as it is possible to get
access to the cable tie.
Ê Thread the two cables through the cable tie.
Ê Take the operating panel module out of its bay.
Ê Push the new operating panel module into its bay as far as it is possible to
have access to the cable tie.
Ê Thread the two cables through the cable tie.
Ê Push the operating panel module into its bay as far as it is possible to plug
the cables.
Replacing the operating panel module