Replacing The Processor - Fujitsu Siemens Computers PRIMERGY TX150 S3 Service Supplement Manual

Server system
Table of Contents

Advertisement

Replacing the processor

Ê Remove the intrusion switch cable from the connector on the system board
(see also the Technical Manual of the system board).
V
CAUTION!
Note the cable routing.
Ê Plug the new intrusion switch cable to the connector on the system board.
Ê Route the intrusion switch cable.
Ê Position the intrusion switch with the three wires on the front cover and
fasten it with two screws.
Ê Insert the intrusion switch with the two wires in its holder and fasten the
switch with two screws.
Ê Reinsert the IDTEMP combo with its holder as shown in figure 12 on
page 25.
Ê Close the server and connect all power plugs (for a detailed description see
the Options Guide).
4.11
Replacing the processor
V
CAUTION!
Processors are modules which can react extremely sensitively to electro-
static discharges and which must therefore always be handled with care.
After a processor has been removed from its protective sleeve or from its
socket, place it with its smooth side down on a non-conducting, antistatic
surface. Never push a processor over a surface.
Ê Open the server as described in the section "Preparation" on page 13.
28
Service Supplement
Replacement routines

Advertisement

Table of Contents
loading

Table of Contents