4.2.4.

Trigger mode

This mode is for starting exposure by synchronization
with the external trigger input (12-pin or 26-pin
connector) and then outputting the individual video
signals of all pixels after the time that was set for the
shutter elapses. There is the edge detection mode for
detecting the rise edge of the external trigger signal and
the width detection mode for detecting the effective
period of the trigger. The period of the external trigger
signal cannot be set shorter than the shutter speed.
Furthermore, if the shutter is set to OFF, the shutter
speed is automatically set to 1/15 s.
Trigger
TRG
FVAL
LVAL
DVAL
Video
output
Trigger mode
Edge detection
More than 67 ms
mode
Width detection
More than 67 ms
mode
Example of positive electrode (The horizontal timing is the same as in the normal mode.)
T 1
T2
T3
2050 H
1
2448 CLK
72 CLK
T1
T2
More than 10 µs
More than 10 µs and
less than 2 s
*
T 4
2050
1
* There is only one LVAL which is less than 2448 CLK during T4
length in order to adjust the timing. T4 changes by depending
on T1.
Shutter
OFF
1/15 s
1/30 s
1/100 s
1/120 s
1/250 s
1/500 s
1/1000 s
1/2000 s
1/5000 s
1/10000 s
1/7.5 s
1/2 s
1 s
2 s
2050
T3 [ms]
68.16
68.16
34.82
11.5
9.82
5.5
3.5
2.5
2
1.7
1.6
134.8
501.5
1000
2000
T2 + 0.52