Table of Contents

Advertisement

Control menu

Menu
Item
ADDR
PSET
PTST
EFSP
FANS
DIM
PERS
DRES
SCUT
DISP
DINT
ERRM
LCAL
Options
Notes (Default settings in bold print)
DMX address (default address = 1). Limited to 496 in 16-bit DMX
1
499
mode.
8BT
8-bit DMX mode
16-bit DMX mode with 2-channel (coarse and fine) control of
16BT
gobo rotation, pan and tilt
PTSP
NORM, FAST and SLOW pan/tilt speed
OFF = Normal pan and tilt control
SWAP
ON = Map DMX pan control to tilt channel and vice versa
OFF = Normal pan control: left
PINV
ON = Reverse DMX pan control: right
OFF = Normal tilt control: up
TINV
ON = Reverse DMX tilt control, down
NORM
Normal effects speed
Optimize effects movement for speed (gives slightly reduced
FAST
smoothness)
Optimize effects movement for smoothness (gives slightly reduced
SLOW
pan/tilt speed)
Pan/tilt speed slave: effects speed copies the pan/tilt speed that has
PTSS
been set via the control menu or via DMX
REG
Temperature-regulated fan operation
FULL
All fans set to full speed
Silent mode. When Silent mode is selected, the head and base fans
run at very low speed. LED output is limited to prevent the fixture
SLNT
from producing too much heat. If the LEDs get too hot, the fans
revert to Regulated mode. When the LEDs are cool enough the
fans shift back to Silent mode.
LIN
Linear dimming curve
SQR
Square law dimming curve
ISQR
Inverse square law dimming curve
SCUR
S-curve dimming curve
OFF
Disable reset via DMX
5SEC
Enable reset via DMX but command must be held for 5 seconds
ON
Enable reset via DMX
OFF
Effect wheels do not cross open
Effect wheels move shortest distance (even if this means
ON
crossing open position)
ON
Display on permanently
2 M
Display auto-sleeps and menu returns to top level after 2 mins.
10M
Display auto-sleeps and menu returns to top level after 10 mins.
Display auto-sleeps and menu returns to top level after 2 mins.,
2 ME
display is reactivated by error messages
Display auto-sleeps and menu returns to top level after 10 mins.,
10ME
display is reactivated by error messages
Display intensity 100% - 10% (default = 50%)
Display errors at 100% intensity (regardless of
NORM
and illuminate the service light.
Silent error mode. The error message does not appear in the
SLNT
display, but the service light is illuminated
Calibration enabled: output limited to maximum default calibrated
ENA
values
Calibration disabled: maximum raw output available (intensity and
DIS
color in different fixtures may not be evenly matched).
Table 4: Control menu
Control menu
right
left
down
up
DINT
setting)
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents