Technical Data - Riello G20KI Instruction Manual

Light oil - kerosene burner
Table of Contents

Advertisement

TECHNICAL DATA

Thermal power – output
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
Burner with CE marking in conformity with EEC Directives: Electromagnetic Compatibility 2004/108/EC,
Low Voltage 2006/95/EC, Machines 2006/42/EC.
The burner meets protection level of IP 40, EN 60529.
8
4
3
1 – Return line
2 – Suction line
3 – Gauge connection
4 – Pump pressure regulator
5 – Vacuum gauge connection
6 – Screws fixing air-damper
7 – Hydraulic jack with air-damper
8 – Lock-out lamp and reset button
7 – Flange with insulating gasket
10 – Combustion head adjustment screw
2403
95 – 213 kW
Light oil, max. viscosity at 20 °C: 4 ÷ 6 mm
Kerosene, max. viscosity at 20 °C: 1.6 ÷ 6 mm
Single phase, 230 V ± 10% ~ 50Hz
Run current 1.4 A – 2750 rpm – 288 rad/s
5 F
Secondary 8 kV – 16 mA
Maximum pressure 14 bar (203 psi)
0.320 kW
Fig. 1
7
6
6
9
D8067
HYDRAULIC JACK OPERATION 7)(Fig. 1)
DANGER
1
8 – 18 kg/h
2
/s (H
It is strongly recommended a periodic check of
the pump pressure operation (annually or bet-
ter every six months, if the burner operation is
continuous).
If the value is lower than 1 bar, compared to
that one of the initial setting, please check the
cleaning of the pump and line filters.
In case the pressure setting was not restora-
ble, please replace the pump, in order to guar-
antee that the pump pressure during the pre-
purge time is at least 3.7 bar.
= 11.86 kWh/kg)
i
2
/s (H
= 11.97 kWh/kg)
i
10
2
1
5