BURNER ELECTRICAL WIRING
240V
N
1
2
Valve
D5228
NOTES
2
– Wires of 1 mm
section.
– The electrical wiring carried out by the installer
must be in compliance with the rules in force in
the Country.
– To remove the control-box from the burner,
loosen screw (A) (see figure) and pull
towards the arrow.
– The photoresistance is fitted directly into the
control-box (underneath the ignition-trans-
former) on a plug-in support.
TESTING
Check the shut-down of the burner by opening the
thermostats.
2403
~
50Hz
L
Main switch
T6A
N
L
3
4
5
6
Black
Capacitor
WARNING
Do not exchange the neutral with the phase.
Remote lock-out signal
(240V - 0.5A max.), if required
Terminal block of
7
8
9
control-box 530SE
M
~
Motor
S7029
RUN OF THE ELECTRICAL CABLE
1 - Cable gland
2 - Cable-clamp
3 - Terminal block
5
Limit thermostat
T
T
Safety thermostat
*
N - Neutral
L - Phase
- Burner-earth