Installation; Remove Icemaker From Carton; Cabinet Removal; Preparation Of Installation Site - Cornelius 500-Series Installation And Service Manual

Continuous flow icemaker
Table of Contents

Advertisement

This section covers unpacking and inspection, selecting location, installing unit, preparing for operation, and op-
eration.
A. REMOVE ICEMAKER FROM CARTON
1. Keep unit in the upright position, remove carton and pallet from unit and inspect unit for damage. Upon in-
spection of unit, if any damage is found, file a claim with carrier immediately.
2. Locate startup card either on outside of container or on plastic liner. Fill in proper information and send one
copy to factory, and other copy to distributor. Postage is prepaid.
B. CABINET REMOVAL
1. Front Panel— Remove 4 screws and pull forward.
2. Top Panel— Remove screws and lift upward. 4 screws 500/700, 6 screws 1000.
3. Side Panel— Remove 4 screws and pull forward.
4. Back Panel— Should not be removed.
C. PREPARATION OF INSTALLATION SITE
1. The refrigeration system on air cooled units requires airflow, so a well ventilated area should be chosen. A
minimum of 6 inches must be maintained, free of any obstructions, for air intake. A minimum of 4 inches
clearance is required for air exhaust.
2. The unit can be installed either on an ice storage bin or ice dispenser using the proper adapter kits. (Refer
to sales literature for information.) The install is kit provided with each icemaker and adapter kits will supply
everything to locate unit correctly. In all cases the icemaker should be sealed all around the base with an
NSF listed sealant. (63804815B)
D. WATER INLET HOOK UP
1. Water Inlet— fitting is a 1/4 SAE male flare located at the rear of the unit. Connect water supply with a 1/4
SAE flare nut and 1/4"copper or flexible tubing or larger.
2. Water Pressure— Unless otherwise specified, the unit is designed to operate on water pressures between
10 P.S.I. and 90 P.S.I. (NOTE: for pressures above 90 P.S.I. a regulator must be installed.)
3. Condenser Inlet Connections— Use a separate 3/8?copper line or larger water line. Connect to 3/8 FPT
fitting on water modulating valve.
4. Filter/Conditioners are recommended on supply lines to icemakers. Never run the water supply to water
cooled condenser through filter/conditioner, it uses up the cartridge unnecessarily and a saturated cartridge
can starve the icemaker causing premature component damage. Separate water supplies are recom-
mended.
NOTE:
Unit must be installed per local plumbing code BOCA.
E. DRAIN CONNECTION
1. Overflow Line— is a 3/8?I.D. flexible tube located at the rear of the unit. Extend this line to proper drain.
2. Condenser Outlet— is a 3/8? FPT located on the rear panel.
NOTE:
Unit must be installed per local plumbing code. BOCA.