F. ELECTRICAL SUPPLY
1. Power Access— is provided with a 7/8? dia. knockout hole in the rear panel. Route incoming power in
conduit, through rear panel to icemaker electrical control box. Make connections to wires provided in the
control box and ground lug/screw.
2. Fused Line— should be checked and sized according to electrical rating shown on unit nameplate.
G. AUGER ENGAGEMENT
Be certain that auger is fully engaged to lower drive and extruding head is fully engaged into evaporator.
H. BIN CONTROL
1. Remove tape holding control to white ice chute and also remove control bracket mounting screw located in
base of unit behind electrical box. (Screw will be used later to fasten bin control bracket to base of unit).
2. Slide control and bracket down chute to base of unit. very carefully guide control and bracket through 1/2?
hole in front of ice chute. Use CAUTION to be sure control goes into bin, not between base of unit and
bin top.
3. Check location of bin control, it should be directly under ice chute at a 45_ angle. With control in place use
mounting screw that was removed in step 1 to secure bracket to base. See Figure 4

INITIAL START UP, CHECKS AND ADJUSTMENT INSTRUCTIONS

NOTE:
Do not start unit before completing installation steps on pages 7 and 9.
Turn on water supply (if unit is water cooled turn water on to condenser also) turn on main power switch (lo-
cated on top of electrical box), and make the following system checks:
NOTE:
If unit will not start be sure water reservoir is full. Low water safety control must be properly
adjusted to start and shut down unit. If water level drops below bottom of reservoir, unit must shut
down. Adjustment is made by moving magnet up or down.
Water Level—
If necessary adjust float by bending float arm up or down as needed, push float assembly down
until unit stops running. Release float and unit will restart. Keep water in reservoir at level line while unit is in
operation. See Figure 5
Low Water Safety Control— Adjust magnet by bending magnet arm as needed to shut unit down if water level
drops below bottom of reservoir.
Bin Control— Place ice around probe, unit should shut down in one minute. Remove ice from around probe,
unit should start in two minutes.