4-1. Indoor Unit

RAS-13SK-E
RAS-13SKX
No.
Parts name
1
Fan motor (for indoor)
Thermo sensor
2
(TA-sensor)
3
DC-DC transformer (T01)
4
Microcomputer
Power relay (RY01),
5
Common relay (RY02)
Heat exchanger sensor
6
(TC-sensor)
7
Line filter (L01)
8
Diode (DB01)
9
Capacitor (C02)
Fuse (F01)
10
11
Power supply IC (IC01)
12
Varistor (R21, R109)
13
Resistor (R01)
14
Louver motor

4-2. Outdoor Unit

RAS-13SA-E
RAS-13SAX
No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Overload relay

4. SPECIFICATIONS OF ELECTRICAL PARTS

Type
ICF-35-19-3
TICF-35-19-3
(microprocessor)
SWT-34
TMP87CK40F
DI1U
(microprocessor)
RF-103YOR6
RBV-406
CEAUF2W101M20
MT3
MA2830-FJ
15G561K
ERF-5TK5R6
MP35EA7
Type
PH160T2-4L2
UE6-31C5P
SK-50FMP
SK-40CMP35U1
J-MRA99253-9200
or
DC35V, 19W
10kΩ at 25°C
DC390V, Secondary DC35V, 12V, 7V
Coil : DC12V 75mA, Rated AC250V 20A
10kΩ at 25°C
10mH, AC 0.6A
4A, 600V
100µF, 450V
T3.15A, 250V
4A, 600V
560V
5.6 Ω, 5W
Output (Rated) 2W, 10poles, 1phase, DC12V
Output (Rated) 1100W, 2pole, 1phase, 220/230/240V, 50Hz
Winding resistance (Ω)
(at 20°C)
Output (Rated) 27W, 6pole, 1phase, 220/230/240V, 50Hz
Winding resistance (Ω)
(at 20°C)
500V AC, 1.5µF
400V AC, 35µF
U/T 10.1A (80°C), OPEN 135±5°C, CLOSE 75±11°C
– 9 –
Specifications
Specifications
Red-Black
2.38
Red-Black
210
White-Black
3.65
White-Black
435