10-3. Outdoor Unit (RAS-13SA-E, RAS-13SAX)
No.
Part name

Common
procedure
Capacitor for
compressor
ƒ
Capacitor for fan
motor
Overload relay
Procedure
1) Stop the operation of air-conditioner, and disconnect
the power cord from the AC supply.
2) Remove E-parts cover.
(2- ST1T ø4 x 10 )
3) Remove the cord clamp (2- ST2T ø4 x 12 ) and
remove the connecting cable.
4) Remove the front cabinet. (8- ST1T ø4 x 10
nylon washer)
• Pull the front lower portion toward you, and remove
it pulling out upward.
1) Perform the process
2) Remove the fixing screw securing the capacitor
band.
(1- ST2T ø4 x 8 )
3) Remove the cable connected to the terminal.

1) Perform the process
2) Remove the fixing screw.
(1- ST2T ø4 x 8 )
3) Remove the cable connected to the terminal.

1) Perform the process
2) Remove terminal cover of compressor.
3) Remove thermo holder and thermostal bimetal up.
4) Remove Fastons of leads.

above.
above.
above.
– 51 –