<When the installation plate is directly mounted
on the wall>
(1) Securely fit the installation plate onto the wall by
screwing it in the upper and lower parts to hook
up the indoor unit.
(2) Install the installation plate horizontally in the wall.
(3) To mount the installation plate on a concrete wall
with anchor bolts, utilize the anchor bolt holes as
shown in the above figure.
CAUTION
When installing the installation plate with mount-
ing screw, do not use the anchor bolt hole. Other-
wise the unit may fall down and result in personal
injury and property damage.
Anchor bolt
Projection
15mm
or less
5mm dia, hole
3 Clip anchor
8 Mounting screw ø4 x 25
CAUTION
Failure to firmly install the unit may result in
personal injury and property damage if the
unit falls.
• In case of block, brick, concrete or similar type
walls, make 5 mm dia, holes in the wall.
• Insert
clip anchors for appropriate
3
ing screws.
NOTE :
• Install the installation plate using 4 to 6 pieces of
mounting screw securing four corners with screws.
Installation plate
(Keep horizontal direction)
Fig. 8-4-4
8

8-4-2. Electrical Work

(1) The supply voltage must be the same as the rated
voltage of the air conditioner.
(2) Prepare the power source for exclusive use with
the air conditioner.
Model
RAS-
13SK-E/
13SA-E
RAS-
13SKX/
13SAX
* No adjustment is necessary.
CAUTION
• Use power specified in above table.
• This appliance can be connected to the mains
in either of the following two ways.
(1) Connection to fixed wiring:
A switch or circuit breaker which disconnects
all poles and has a contact separation of at
least 3 mm must be incorporated in the fixed
wiring. An approved circuit breaker or switches
must be used.
(2) Connection with power supply plug:
Attach power supply plug with power cord and
plug it into wall outlet. An approved power
supply cord and plug must be used.
NOTE :
• Perform wiring works so as to allow a generous
wiring capacity.
mount-
– 23 –
Maximum
running
Power source
current
50Hz
*220/230/240V~
7.5 A
Single-phase
Plug
socket
Wiring
& fuse
rating
2
1.3mm
16 A
or
more