York HA090 Technical Manual page 181

Split-system air-cooled condensing units
Table of Contents

Advertisement

Model DE Specifications
T T h h e e U U V V C C E E m m i i t t t t e e r r
and fixture shall be factory assembled and
TM
tested. They shall consist of a housing, power source, reflector,
Emitter sockets and Emitter.
T T h h e e h h o o u u s s i i n n g g shall be constructed of 304 stainless steel to withstand
HVAC environments. The reflector shall be constructed of heavy
gauge, specular finished aluminum alloy with approximately 85%
reflectance at 254 nm wavelength. The housing shall be equipped
with 1/2" electrical conduit openings on each end to facilitate
coupling and wiring fixture-to-fixture and to power. All components
shall be in one integral assembly to maximize serviceability.
T T h h e e p p o o w w e e r r s s o o u u r r c c e e shall be a Class P2, electronic, rapid start type
with a power factor greater than 0.95 and a power conversion of
greater than 75%. The power supply design shall include RF and EMI
suppression. The power supply shall be designed to maximize photon
production, irradiance and reliability in cold or moving airstreams of
35-170° F, 100% RH and up to 2000 fpm velocity. The fixture shall
This product may be covered by one or more of the following patents, others pending: 5,334,347/ 5,866,076/ 5,817,276/ 6,372,186/ 6,313,470/ 6,245,293/
6,267,924/ 6,280,686/ 6,423,882.
Ordering Information
Model No.
Part No.
DE 181 VO
10001500
DE 181 VO
10002100
DE 241 VO
10001600
DE 241 VO
10002200
DE 301 VO
10001700
DE 301 VO
10002300
DE 361 VO
10001800
DE 361 VO
10002400
DE 421 VO
10001300
DE 421 VO
10002500
GTD 16 VO
20000100
GTD 22 VO
20000200
GTD 28 VO
20000300
GTD 34 VO
20000400
GTD 40 VO
20000500
Steril-Aire, Inc.
Corporate Office:
2840 N. Lima Street
Burbank, CA 91504
Telephone: 818-565-1128
Fax: 818-565-1129
Website: www.steril-aire.com
Email: sales@steril-aire.com
© 2003 Steril-Aire
http://www.rezine.net
Description
Double-Ended Fixture
Double-Ended Fixture
Double-Ended Fixture
Double-Ended Fixture
Double-Ended Fixture
Double-Ended Fixture
Double-Ended Fixture
Double-Ended Fixture
Double-Ended Fixture
Double-Ended Fixture
Replacement Emitter –DE 181
Replacement Emitter –DE 241
Replacement Emitter –DE 301
Replacement Emitter –DE 361
Replacement Emitter –DE 421
®
1100-07/05
Page 181
be available in 115-208/230 or 277 Vac, 50/60 Hertz, and single phase.
T T h h e e E E m m i i t t t t e e r r s s o o c c k k e e t t s s are medium bi-pin, double click safety, twist
lock type. They shall be constructed of UVC-resistant polycarbonate.
T T h h e e E E m m i i t t t t e e r r t t u u b b e e shall be a very high output, hot cathode, T5
diameter, medium bi-pin type that produces broadband UVC of 250-
260 nm. Each tube shall produce the specified output at 2000 fpm
velocity and air temperatures of 35-170° F. It shall produce no ozone
or other secondary contaminants.
I I n n d d e e p p e e n n d d e e n n t t t t e e s s t t i i n n g g : : The unit shall be tested by an independent test
laboratory in accordance with the general provisions of IES Lighting
Handbook, 1981 Applications Volume, and shall be verified through
independent testing to provide output per 1" arc length of not less
than 10 μW/cm2 at 1 meter in a 400 fpm airstream of 45° F.
Unit shall comply with UL Standard 1995 for use in HVAC
equipment and shall carry the "UL" and "ULC" labels.
Length
Electrical
18"
115, 208, 230V: 70-85 watts
18"
277V: 70-85 watts
24"
115, 208, 230V: 70-85 watts
24"
277V: 70-85 watts
30"
115, 208, 230V: 70-85 watts
30"
277V: 70-85 watts
36"
115, 208, 230V: 70-85 watts
36"
277V: 70-85 watts
42"
115, 208, 230V: 70-85 watts
42"
277V: 70-85 watts
16"
N/A
22"
N/A
28"
N/A
34"
N/A
40"
N/A
Complies with current U.S. and Canadian UL Standards for
use in HVAC equipment.
Represented By:
Weight
2.3 lb.
2.3 lb.
2.7 lb.
2.7 lb.
3.3 lb.
3.3 lb.
3.7 lb.
3.7 lb.
4.1 lb.
4.1 lb.
0.15 lb.
0.15 lb.
0.20 lb.
0.25 lb.
0.25 lb.

Hide quick links: