*TC/TL FURNACES WITH VARIABLE SPEED BLOWERS
"C" CABINET
Switch Settings
(0 = OFF, 1 = ON)
HEAT
COOL
1-4
5
6
7
8
LOW
#
0
0
0
0
705
#
0
0
0
1
750
#
0
0
1
0
795
#
0
0
1
1
840
#
0
1
0
0
885
#
0
1
0
1
930
#
0
1
1
0
975
#
0
1
1
1
1,020
#
1
0
0
0
1,065
#
1
0
0
1
1,110
#
1
0
1
0
1,155
#
1
0
1
1
1,200
#
1
1
0
0
1,245
#
1
1
0
1
1,290
#
1
1
1
0
1,335
#
1
1
1
1
1,380
# Switch not used - can be 0 or 1
Table 10. Nominal Cooling/Heat Pump Airfl ows (CFM) for Variable Speed Furnaces
CFM
Nominal A/C and
HP Capacity
HIGH
1,025
1,090
1,155
1,220
1,285
1,350
1,415
1,480
1,545
1,610
1,675
1,740
1,805
1,870
1,935
2,000
*TC/TL FURNACES WITH VARIABLE SPEED BLOWERS
"B" CABINET
Switch Settings
(0 = OFF, 1 = ON)
HEAT
COOL
1-4
5
6
7
8
LOW
1
0
0
0
0
485
1
0
0
0
1
525
1
0
0
1
0
565
1
0
0
1
1
605
1
0
1
0
0
650
1
0
1
0
1
690
1
0
1
1
0
730
1
0
1
1
1
775
1
1
0
0
0
815
1
1
0
0
1
855
1
1
0
1
0
895
1
1
0
1
1
940
1
1
1
0
0
980
1
1
1
0
1
1,020
1
1
1
1
0
1,065
1
1
1
1
1
1,105
*TC/TL FURNACES WITH VARIABLE SPEED BLOWERS
"D" CABINET
Switch Settings
(0 = OFF, 1 = ON)
HEAT
COOL
1-4
5
6
7
8
LOW
#
0
0
0
0
965
#
0
0
0
1
995
#
0
0
1
0
1,020
#
0
0
1
1
1,050
#
0
1
0
0
1,075
#
0
1
0
1
1,105
#
0
1
1
0
1,130
#
0
1
1
1
1,160
#
1
0
0
0
1,185
#
1
0
0
1
1,215
#
1
0
1
0
1,240
#
1
0
1
1
1,270
#
1
1
0
0
1,295
#
1
1
0
1
1,325
#
1
1
1
0
1,350
#
1
1
1
1
1,380
CFM
Nominal A/C and HP
Capacity
HIGH
700
760
820
880
940
1,000
1,060
1,120
1,180
1,240
1,300
1,360
1,420
1,480
1,540
1,600
CFM
Nominal A/C and HP
Capacity
HIGH
1,400
1,440
1,480
1,520
1,560
1,600
1,640
1,680
1,720
1,760
1,800
1,840
1,880
1,920
1,960
2,000
37