Furnace
Input
(Btuh)
60,000
80,000
100,000
120,000
** Time-delay fuses or HACR-type circuit breakers are required.
Thermostat Wire Gauge
24
22
20
18
Black (Hot)
White (Neutral)
Green or Bare
(Ground)

Twinning

The control boards on fi xed speed furnaces are capable
of being twinned to other furnace of the same series, only
if the following criteria are met:
• The circuit boards are the same.
• The thermostat wires and the 1/4 inch thick quick-connect
terminals marked "TWIN" (Figure 26) on the furnace
controls must be connected together.
• The fuses must remain installed on each board.
• Twinned furnaces must be properly grounded according
to local codes.
• The autostage jumper must be set to the same pin
setting on both furnace control boards.
Note: Variable speed furnaces cannot be twinned.
26
Cabinet
Nominal
Width
Electrical
(in.)
Supply
½
115-60-1
17
21
115-60-1
21
115-60-1
½
115-60-1
24
Table 5. Wire Length and Voltage Specifi cations
Field Supplied
Field Supplied
Fused Service
Disconnect w/in
Panel
Sight of Furnace
Black
White
Ground
Field Line Voltage Wiring
Factory Line Voltage Wiring
Figure 25. Line Voltage Field Wiring
Maximum
Minimum
Operating
Operating
Voltage
Voltage
127
103
127
103
127
103
127
103
Recommended Thermostat Wire Length
2 - wire
(Heating)
55 ft.
90 ft.
140 ft.
225 ft.
Junction Box (may be int. or ext.
to the furnace). These connections
can be made in the field supplied
disconnect at the furnace.
White
Ground
Field Supplied
Panel Connector
THERMOSTAT
W2
W1 G Y R
UNIT
Maximum
Minimum
Furnace
Wire
Amperes
Gauge
7.0
14
9.4
14
9.4
14
12.5
14
4 or 5 wire
(Cooling)
25 ft.
45 ft.
70 ft.
110 ft.
Black
Black
White
R
C
Y
G
W1
W2
FURNACE
BOARD
FSHE
BOARD
TWIN TERMINAL
A/C
FURNACE 1
Figure 26. Twinning
Maximum
Fuse or Circuit
Breaker Amps**
15
20
20
25
Ground
R
C
Y
G
W1
W2
FURNACE
BOARD
FSHE
BOARD
TWIN TERMINAL
FURNACE 2