IBM TotalStorage DS4000 Hardware Maintenance Manual page 101

Hide thumbs Also See for TotalStorage DS4000:
Table of Contents

Advertisement

Table 31. DS4300 RAID controller LEDs (continued)
Icon
LED
Cache active Green
Battery
+
Expansion
port bypass
Loop
No icon
2 Gbps
No icon
10BT
No icon
100BT
1
Always use the storage management software to identify the failure.
Color
Operating states
v On - There is data in the RAID
controller cache.
v Off - One of the following situations
has occurred:
– There is no data in the cache.
– There are no cache options selected
for this array.
– The cache memory failed, or the
battery failed.
Green
v On - Normal operation
v Flashing - The battery is recharging or
performing a self-test.
v Off - The battery or battery charger
failed.
Amber
v Off - Normal operation
v On - One of the following situations
has occurred:
– An SFP module is inserted in the
drive loop port and the fibre channel
cable is not attached to it.
– The fibre channel cable is not
attached to an expansion unit.
– The attached expansion unit is not
turned on.
– An SFP failed, a fibre channel cable
failed, or an SFP failed on the
attached expansion unit.
Note: There is no Expansion port bypass
LED on the DS4300 model 6LU and 6LX
storage server.
Green
v On - Normal operation
v Off - The RAID controller circuitry
failed, or the RAID controller has no
power.
Green
v On - Normal operation (host connection
is at 2 Gbps)
v Off - Host connection is at 1 Gbps
(which is not supported for controller
firmware 05.33.xx.xx).
Green
v If the Ethernet connection is
10BASE-T: The 10BT LED is on; the
100BT LED flashes faintly.
v If the Ethernet connection is
100BASE-T: The 10BT LED is off; the
100BT LED is on.
v If there is no Ethernet connection:
Both LEDs are off.
Chapter 9. Type 1722 DS4300 Storage Server
1
73

Hide quick links:

Advertisement

Table of Contents
loading