System Beep Codes

When an error that cannot be reported on the monitor occurs during a boot routine, the system may emit a series of beeps
that identifies the problem.
When a beep code is emitted, record it on a copy of the Diagnostics Checklist in
Table
2-11. If you are unable to resolve the problem by looking up the meaning of the beep code, use the system diagnostics
to identify a more serious cause. If you are still unable to resolve the problem, see
NOTE:
If the system boots without a keyboard, mouse, or monitor attached, the system will not issue beep codes
related to those peripherals.
NOTE:
Before you perform any procedures described in
System."
Table 2-11. System Beep Codes
Code
Cause
1-1-2
CPU register test failure.
1-1-3
CMOS write/read failure;
faulty system board.
1-1-4
BIOS error.
1-2-1
Programmable interval-timer
failure; faulty system board.
1-2-2
DMA initialization failure.
1-2-3
DMA page register write/read
failure.
1-3-1
Main-memory refresh
verification failure.
1-3-2
No memory installed.
1-3-3
Chip or data line failure in the
first 64 KB of main memory.
1-3-4
Odd/even logic failure in the
first 64 KB of main memory.
1-4-1
Address line failure in the first
64 KB of main memory.
1-4-2
Parity failure in the first 64 KB
of main memory.
1-4-3
Fail-safe timer test failure.
1-4-4
Software NMI port test
failure.
Bit failure in the first 64 KB of
2-1-1
through
main memory.
2-4-4
3-1-1
Slave DMA-register failure.
3-1-2
Master DMA-register failure.
Faulty diskette,
CD/diskette drive
assembly, hard drive, or
hard-drive subsystem.
Table
Corrective Action
Replace microprocessor 1. See
"Installing System Board Options." If the problem persists, replace microprocessor
2.
See
"Getting
Help."
Reflash the BIOS firmware (see
See
"Getting
Help."
See
"Troubleshooting System
See
"Getting
Help."
See
"Troubleshooting the Diskette
"Troubleshooting a CD
"Troubleshooting Hard
"Troubleshooting Your System."
"Abbreviations and
"Getting
Help," and then look it up in
"Getting
2-11, see
"Before You
Begin" in "Troubleshooting Your
"Adding or Replacing a
"Getting
Help").
Memory" in "Troubleshooting Your System."
Drive,"
Drive," and
Drives" in
Acronyms."
Help."
Microprocessor" in

Advertisement

Table of Contents
loading

Table of Contents