Advertisement

E0212
VOLT PLANAR
REG
E0276
CPU VRM n
E0276
MISMATCH VRM
n
E0280
MISSING VRM
n
E0319
PCI OVER
CURRENT
E0412
RPM FAN n
E0780
MISSING CPU
1
E07F0
CPU IERR
E07F1
TEMP CPU n
HOT
E07F4
POST CACHE
E07F4
POST CPU REG
POST CPU SMI SMI handler failed to initialize;
E07F4
E07FA
TEMP CPU n
THERM
E0876
POWER PS n
E0880
INSUFFICIENT
PS
E0CB2
MEM SPARE
ROW
E0CF1
MBE DIMM
Bank n
POST MEM 64K Parity failure in the first 64 KB of
E0CF1
E0CF1
POST NO
MEMORY
E0CF5
LOG DISABLE
SBE
E0D76
DRIVE FAIL
System board is out of acceptable
voltage range; faulty or
improperly installed system board.
Specified microprocessor VRM is
faulty, unsupported, improperly
installed, or missing.
Faulty or improperly installed
expansion card.
Specified cooling fan is faulty,
improperly installed, or missing.
Microprocessor is not installed in
socket 1.
Faulty or improperly installed
microprocessor.
Specified microprocessor is out of
acceptable temperature range and
has halted operation.
Faulty or improperly installed
microprocessor.
faulty system board.
Specified microprocessor is out of
acceptable temperature range and
is operating at a reduced speed,
or frequency.
No power available from the
specified power supply; specified
power supply is improperly
installed or faulty.
Insufficient power is being
supplied to the system; power
supplies are improperly installed,
faulty, or missing.
Correctable errors threshold was
met in a memory bank: errors
were remapped to the spare row.
Memory modules installed in the
specified bank are not the same
type and size; faulty memory
module(s).
main memory.
Main-memory refresh verification
failure.
Multiple single-bit errors on a
single memory module.
Faulty or improperly installed hard
drive or RAID controller.
See
"Troubleshooting Power
Your System."
Ensure that supported VRMs of the same type are properly
installed. If the problem persists, replace the VRM (see
Figure 6-9
in "Installing System Options").
See
"Troubleshooting Expansion
Your System."
See
"Troubleshooting a Cooling
Your System."
Install a microprocessor in socket 1 (see
Replacing a
Microprocessor" in "Installing System Options").
To identify microprocessor socket 1, see
See
"Troubleshooting a
Microprocessor" in "Troubleshooting
Your System."
See
"Troubleshooting System
Your System." If the problem persists, ensure that the
microprocessor heat sinks are properly installed (see
"Adding or Replacing a
Microprocessor" in "Installing System
Options").
See
"Troubleshooting a
Microprocessor" in "Troubleshooting
Your System."
See
"Getting
Help."
See
"Troubleshooting System
Your System." If the problem persists, ensure that the
microprocessor heat sinks are properly installed (see
"Adding or Replacing a
Microprocessor" in "Installing System
Options").
See
"Troubleshooting Power
Your System."
See
"Troubleshooting Power
Your System."
See
"Troubleshooting System
Your System."
Ensure that all banks contain memory modules of the same
type and size and that they are properly installed. If the
problem persists, see
"Troubleshooting System
"Troubleshooting Your System."
See
"Troubleshooting System
Your System."
Ensure that all banks contain memory modules of the same
type and size and that they are properly installed. If the
problem persists, see
"Troubleshooting System
"Troubleshooting Your System."
See
"Troubleshooting System
Your System."
See
"Troubleshooting Hard
RAID Controller
Card" in "Troubleshooting Your System."
Supplies" in "Troubleshooting
Cards" in "Troubleshooting
Fan" in "Troubleshooting
"Adding or
Figure
A-3.
Cooling" in "Troubleshooting
Cooling" in "Troubleshooting
Supplies" in "Troubleshooting
Supplies" in "Troubleshooting
Memory" in "Troubleshooting
Memory" in
Memory" in "Troubleshooting
Memory" in
Memory" in "Troubleshooting
Drives" and
"Troubleshooting a