Weil-McLain Gold CGi 2 Series Manual page 66

Gold cgi gas-fired water boilers series 2
Hide thumbs Also See for Gold CGi 2 Series:
Table of Contents

Advertisement

CGi
GOLD
GAS-FIRED WATER BOILER — SERIES 2 —
13b
Ratings
Table 10 Boiler ratings
DOE
Boiler
Heating
model
capacity
number
(Btuh)
(Note 1)
(Note 2)
CGi-25
42,000
CGi-3
51,000
(Note 5)
CGi-4
85,000
CGi-5
100,000
CGi-6
140,000
CGi-7
167,000
CGi-8
194,000
1. Add "PIN" for natural gas boiler - "PIL" for Liquefied Petroleum (propane) gas boiler.
2. Based on standard test procedures prescribed by the United States Department of Energy.
3. Net I=B=R ratings are based on net installed radiation of sufficient quantity for the requirements of
the building and nothing need be added for normal piping and pickup. Ratings are based on a piping
and pickup allowance of 1.15. An additional allowance should be made for unusual piping and pickup
Notes
loads.
4. CGi boilers require special venting, consistent with Category I or III boiler. Use only the vent materials
and methods specified in this manual. Vent diameter shown above is for direct exhaust venting. See
Table 3, page 14, for vent diameter when chimney draft venting.
5.
As an Energy Star Partner, Weil-McLain has determined that the CGi-3 meets the Energy Star guidelines for
energy efficiency.
CGi boilers for residential radiant panel systems, converted gravity heating systems or other low water tempera-
ture applications should be installed with balancing valves and bypass piping equal to the supply and return
size to avoid excessive flue gas condensation due to lower operating water temperatures. For alternate piping,
contact your Weil-McLain sales office. CSA design certified for installation on combustible flooring. Tested for
50 psi working pressure.
66
0 - 2,000 feet
2,000 - 4,500 feet
altitude
Input
Output
(Btuh)
(Btuh)
(Btuh)
50,000
42,000
45,000
60,000
51,000
60,000
100,000
85,000
90,000
119,000
100,000
120,000
167,000
140,000
150,000
200,000
167,000
180,000
233,000
194,000
210,000
Boiler Manual
Net
I=B=R
altitude
ratings
(Btuh)
Input
Output
(Note 3)
(Btuh)
38,000
37,000
51,000
45,000
76,000
74,000
101,000
87,000
126,000
122,000
150,000
145,000
175,000
169,000
Boiler
DOE
water
Seasonal
Vent size
content
efficiency
(gallons)
(% AFUE)
(Note 5)
(Note 4)
1.5
84.0
1.5
85.1
2.1
84.0
2.7
83.3
3.3
83.3
3.8
83.0
4.4
82.7
Part Number 550-110-710/1211
(Note 5)
3"
3"
3"
3"
3"
3"
3"