GOLD
Series 2 Gas-Fired Water Boiler
High Altitude Conversion Kit
Instructions
2,000 to 10,000 feet

Hazard definitions

The following terms are used throughout these Instructions to bring attention to the presence
of hazards of various risk levels or to important information concerning the life of the product.
Indicates presence of hazards that will cause severe personal injury, death
or substantial property damage.
Indicates presence of hazards that can cause severe personal injury, death
or substantial property damage.
Indicates presence of hazards that will or can cause minor personal injury
or property damage.
Indicates special instructions on installation, operation or maintenance that
are important but not related to personal injury or property damage.
Note to the installer
Failure to follow the limitations listed below will cause severe personal injury,
death or substantial property damage.
Do not use this kit to convert a CGi boiler from natural gas to propane
gas or from propane gas to natural gas.
Use only the kit specified for the CGi boiler being converted.
This conversion kit must only be installed by a Weil-McLain distributor or
other qualified technician in accordance with these Instructions and all
applicable codes and requirements of the authority having jurisdiction. Read
these instructions completely before beginning the installation. If the
information in these Instructions is not followed exactly, a fire, explosion,
carbon monoxide emission or other hazardous conditions can result,
causing severe personal injury, death or substantial property damage. The
qualified technician performing this work assumes responsibility for this
conversion.
CGi
Part Number 550-141-890/0300

Advertisement

loading

Summary of Contents for Weil-McLain Gold CGi 2 series

  • Page 1: Hazard Definitions

    • Use only the kit specified for the CGi boiler being converted. This conversion kit must only be installed by a Weil-McLain distributor or other qualified technician in accordance with these Instructions and all applicable codes and requirements of the authority having jurisdiction. Read these instructions completely before beginning the installation.
  • Page 2: Conversion Instructions

    GOLD Series 2 Gas-Fired Water Boiler Conversion instructions For the boiler to operate correctly 3. Affix “High Altitude Conversion Label” above boiler at high altitude, you must replace rating label. Affix “Consumer Protection Label” the main burner orifices and the air above the boiler CP label.
  • Page 3 High Altitude Conversion Kit Instructions Parts Table 1 Natural gas conversion kit Table 2 Propane gas conversion kit Boiler Altitude Kit part Main Boiler Altitude Kit part Main model (feet) number burner pressure model (feet) number burner pressure number orifices switch number orifices...
  • Page 4 GOLD Series 2 High Altitude Conversion Kit Instructions Part Number 550-141-890/0300...