TABLE
5.5
TYPICAL VOL TAGES AND RESISTANCES
(A) Inter-unit terminal board
Note:
Resistance measurements shall be made under the following conditions:
IOPERATE
I
switch-OFF,j S101j-ON
Resistance value shall be measured between measuring point and ground unless otherwise
specified, and negative terminal of the tester is grounded as a rule.
The tester used this measurement is 20 kfJ./V de,
8
kD./V ac.
Voltage measurement shall be made under the following conditions:
,
JOPERATE
I
switch-ON,
I
RAIN CLUTTER
I
switch-OFF,
I
GAIN/-max,
I
SEA CLUTTER
I
-min.
Ship's power supply is de 12 V.
SCANNER UNIT
Measuring
Resistance
Voltage (V)
0.25
0.5
1
2
4
8
12
Remarks
Point
Hl)
nm
nm
nm
nm
nm
nm
nm
TBIOI MH
22
340
340
340
340
330
330
330
DC 1200 V
MI
78
1
0 . 02
0.02
0.02
0.02
0.02
0.02
0.02
DC 0.3 V
PI
300
i
12
12
12
12
0.8
0.8
0.8
DC 30 V
6
6
12
12
12
12
12
12
12
DC 30 V
GS
53
4.7
4.7
4.7
4.7
4.7
4.7
4.7
DC 12 V
VD
55
0.13
0.13
0.13
0.13
0.13
0.13
0.13
DC 0.3 V
I
33
6.5 k
7
7
7
7
I
7
7
7
DC30 V
38
600
5
5
5
5
5
5
5
DC30V
DP
460
7.5
7.5
7.5
7.5
7.5
7.5
7.5
I
AC30 V
5-10