Filters; Dimensions; Side Return Cutout Markings; Cabinet And Duct Dimensions - Johnson Controls TP9C C Installation Manual

Residential gas furnace with ecm motor
Hide thumbs Also See for TP9C C:
Table of Contents

Advertisement

LEFT SIDE
Combustion Air Inlet
Condensate Drain
(Downflow)
2" Vent
Connection
Outlet
28.5"
29.5"
(For Cladded door add appoximately an additional .75")
.56"
23.8"
Combustion
B
Air Inlet
.56"
.56"
20"
SUPPLY END
FIGURE 13: Dimensions
Table 3: Cabinet and Duct Dimensions
Nominal
BTUH (kW)
3
Input
CFM (m
60 (17.6)
1200 (34.0)
80 (23.4)
1200 (34.0)
80 (23.4)
1600 (45.3)
100 (29.3)
1600 (45.3)
100 (29.3)
2000 (56.6)
120 (35.1)
2000 (56.6)
SECTION III: FILTERS
FILTER INSTALLATION
All applications require the use of a field installed filter. All filters and
mounting provision must be field supplied.
Filters must be installed external to the furnace cabinet. DO NOT
attempt to install filters inside the furnace.
NOTICE
Single side return above 1800 CFM is approved as long as the filter
velocity does not exceed filter manufacturer's recommendation and
a transition is used to allow use on a 20x25 filter.
Table 4: Recommended Filter Sizes (High Velocity 600 FPM)
CFM
Cabinet
(m³/min)
Size
1200 (34.0)
B
1600 (45.3)
C
2000 (56.6)
C
2000 (56.6)
D
1.Air velocity through throwaway type filters may not exceed 300 feet per minute
(91.4 m/min). All velocities over this require the use of high velocity filters.
2.Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the bot-
tom or one side return with a transition to allow use of a 20x25 filter.
Johnson Controls Unitary Products
Gas Pipe
Entry
Electrical
Entry
Condensate
Drain
Thermostat
Wiring
3"
2" Vent
Connection
Outlet
C
Cabinet
Size
/min)
B
17 1/2
B
17 1/2
C
C
C
D
24 1/2
Side
Bottom
(in)
(in)
16 x 25
16 x 25
16 x 25
20 x 25
(2) 16 x 25
20 x 25
(2) 16 x 25
22 x 25
FRONT
Gas Pipe
Entry
Electrical
Entry
33
Condensate
Drain
Thermostat
Wiring
A
Cabinet Dimensions (Inches)
A
A (cm)
44.4
16 3/8
44.4
16 3/8
21
53.3
19 7/8
21
53.3
19 7/8
21
53.3
19 7/8
62.2
23 3/8
SIDE RETURN
Locate the "L" shaped corner locators. These indicate the size of the cut-
out to be made in the furnace side panel. Refer to Figure 14.
Install the side filter rack following the instructions provided with that
accessory. If a filter(s) is provided at another location in the return air
system, the ductwork may be directly attached to the furnace side panel.
FIGURE 14: Side Return Cutout Markings
Some accessories such as electronic air cleaners and pleated
media may require a larger side opening. Follow the instructions
supplied with that accessory for side opening requirements. Do not
cut the opening larger than the dimensions shown in Figure 13.
RIGHT SIDE
Combustion Air Inlet
Condensate Drain
(Downflow)
2" Vent
Connection
Outlet
23"
Optional Return Air
Cutout (Either side)
24.25"
RETURN END
B
B (cm)
C
41.6
13 1/4
41.6
14 3/4
50.5
16 1/2
50.5
18 1/4
50.5
18 1/4
59.4
21 3/4
681292-UIM-A-0211
14"
1"
1.5"
B
C (cm)
33.7
37.5
41.9
46.4
46.4
55.2
Front of
Furnace
Side of
Furnace
Corner
Markings
9