FIGURE 8: Dimensions
Table 2: Cabinet and Duct Dimensions
Nominal
BTUH (kW)
3
Input
CFM (m
40 (11.7)
1000 (28.3)
60 (17.6)
1200 (34.0)
80 (23.4)
1200 (34.0)
80 (23.4)
1600 (45.3)
100 (29.3)
1600 (45.3)
100 (29.3)
2000 (56.6)
120 (35.1)
2000 (56.6)
SECTION III: FILTERS
FILTER INSTALLATION
CAUTION
!
All filters and mounting provision must be field supplied. All installa-
tions must have a filter installed.
All applications require the use of a field installed filter. All filters and
mounting provision must be field supplied.
Filters must be installed external to the furnace cabinet. DO NOT
attempt to install filters inside the furnace.
NOTICE
Single side return above 1800 CFM is approved as long as the filter
velocity does not exceed filter manufacturer's recommendation and a
transition is used to allow use on a 20x25 filter.
8
Cabinet
Size
/min)
A (in)
A
14 1/2
B
17 1/2
B
17 1/2
C
21
C
21
C
21
D
24 1/2
Cabinet Dimensions (Illustrated in Figure 8)
A (cm)
B (in)
B (cm)
36.8
13 3/8
34.0
44.4
16 3/8
41.6
44.4
16 3/8
41.6
53.3
19 7/8
50.5
53.3
19 7/8
50.5
53.3
19 7/8
50.5
62.2
23 3/8
59.4
Table 3: Recommended Filter Sizes (High Velocity 600 FPM)
CFM
(m³/min)
1000 (28.3)
1200 (34.0)
1600 (45.3)
2000 (56.6)
2000 (56.6)
1. Air velocity through throwaway type filters may not exceed 300 feet per
minute (91.4 m/min). All velocities over this require the use of high velocity

filters.

2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For
CFM greater than 1800, you may use two side returns or one side and the
bottom or one side return with a transition to allow use of a 20x25 filter.
Operating Weights
C (in)
C (cm)
11 3/4
29.8
13 1/4
33.7
14 3/4
37.5
16 1/2
41.9
18 1/4
46.4
18 1/4
46.4
21 3/4
55.2
Cabinet
Side
Size
(in)
A
16 x 25
B
16 x 25
C
16 x 25
C
(2) 16 x 25
D
(2) 16 x 25
Johnson Controls Ducted Systems
Approximate
Lbs (kg)
113 (51.2)
122 (55.3)
126 (57.1)
136 (61.7)
142 (64.4)
145 (65.8)
156 (70.7)
Bottom
(in)
14 x 25
16 x 25
20 x 25
20 x 25
22 x 25

Advertisement