Johnson Controls TPLC060A12MP12C Quick Reference Manual

80% modulating ecm multi-position residental gas furnaces (33” tall)

Advertisement

Quick Links

NOTES:
1.
If the furnace is equipped with NOx screens and is to be
used with LP (propane) gas, the screens must be removed
prior to start-up.
2.
Drip leg in the gas line must be installed.
3.
The furnace controls require correct polarity on the power
supply and a proper ground.
4.
Y & G must be connected to the control board for cooling
operation.
5.
External filters required on all configurations.
Airflow CFM (Bottom Return without Filters)
Models
0.5" ESP (Nominal)*
D-A
C-A
(T,Y,C,L)PLC060A12MP12C
600
815
(T,Y,C,L)PLC080B12MP12C
580
775
(T,Y,C,L)PLC080C16MP12C
1000
1200
(T,Y,C,L)PLC100C16MP12C
980
1165
(T,Y,C,L)PLC100C20MP12C
1140
1330
(T,Y,C,L)PLC120C20MP12C
1200
1400
Input
Total Unit
Rate
Models
Max
Min
(T,Y,C,L)PLC060A12MP12C
60,000
30,000
(T,Y,C,L)PLC080B12MP12C
80,000
40,000
(T,Y,C,L)PLC080C16MP12C
80,000
40,000
(T,Y,C,L)PLC100C16MP12C
100,000
50,000
(T,Y,C,L)PLC100C20MP12C
100,000
50,000
(T,Y,C,L)PLC120C20MP12C
120,000
60,000
* Other airflows are available. see Tech guide for all CFM options.
LED INDICATOR
Slow Green Flash - Normal operation in standby mode
Slow Amber Flash - Normal operation with call for cooling
Two Amber Flashes - Normal operation with call for heat
Subject to change without notice. Published in U.S.A.
Copyright © 2009 by Johnson Controls, Inc. All rights reserved.
Johnson Controls Unitary Products
Norman, OK 73069
6.
Electrical or gas entry is available on both casing sides.
7.
To measure total static pressure add supply duct pressure to
the return duct pressure, add pressure drop across the 'A'
coil, and add pressure drop across the filter. Ignore negative
signs on the readings.
8.
Inlet gas pressure for natural gas should be 7" and for pro-
pane should be 11" w.c. Nominal manifold gas pressure is
3.5" for natural gas and 10" w.c. for propane at max. input.
9.
For downflow application the vent blower must be rotated 90
left or right as shown.
Minimum Wire
Size awg @ 75'
One-Way
B-A
A-B
1050
1340
14
960
1290
14
1395
1715
14
1345
1600
14
1515
2110
12
1510
1990
12
Time For 1 ft
Air Temp. Rise
Air Temp. Rise
(1030 Btu/Ft
Amps
Max Input °F
Min Input °F
(On Max. Rate)
7.0
30-60
20-50
7.5
40-70
20-50
10.0
35-65
20-50
10.0
35-65
20-50
12.0
35-65
20-50
12.0
45-75
25-55
Three Amber Flashes - Normal operation, burner is on at end of
thermostat cycle.
Six Amber Flashes - Normal operation with call for heat pump
heating.
Any Red Flash - Fault condition
*535679*
535679-URG-A-0909
Supersedes: Nothing
5005 York Drive
This document does not replace the installation instructions, which must be referred to for
detailed information.
SUPPLY END
.5"
24.38"
B
.5"
20"
Maximum
Over Current
Protection
15
15
15
15
20
20
3
Natural Gas
3
) Seconds
62
46
(For Cladded door add
46
appoximately an additional .75")
37
LEFT SIDE
37
Follow all national, local codes and standards in addition to this document. The installation
must comply with regulations of the serving gas supplier, local building, heating, plumbing,
30
and other codes. In absence of local codes, the installation must comply with the national
codes and all authorities having jurisdiction.
CLEARANCES
Application
Top
B-Vent
Rear
Side
Front*
Floor
Combustible
Closet
Line Contact
1. For combustible floors only when used with special
sub-base.
* 24" clearance in front and 18" on side recommended for
service access.
All furnaces approved for alcove and attic installation.
QUICK REFERENCE GUIDE
80% MODULATING ECM MULTI-POSITION
RESIDENTAL GAS FURNACES (33" TALL)
RETURN END
4" Diameter
Vent Connection
Outlet
B
Electrical
24.25"
Entry
Vent
Connection
Outlet
Electrical
Entry
Gas Pipe
Entry
23"
Thermostat
Wiring
28.5"
29.5"
RIGHT SIDE
DIMENSIONS
Upflow
Downflow
Horizontal
1"
0"
0"
All 'A' Cabinet Furnaces
1"
1"
1"
All 'B' Cabinet Furnaces
0"
0"
0"
All 'C' Cabinet Furnaces
0"
0"
1"
0"
0"
0"
1
Combustible
Combustible
Yes
Yes
Yes
No
No
Yes
.5"
.5"
Clips can be flipped
into the up position
for coil cabinet or
plenum attachment
A-COIL
14"
33"
1"
1.5"
A
FRONT
Cabinet Size
A (in)
B (in)
14-1/2"
13-3/8"
17-1/2"
16-3/8"
21"
19-7/8"

Advertisement

loading

Summary of Contents for Johnson Controls TPLC060A12MP12C

  • Page 1 Subject to change without notice. Published in U.S.A. *535679* 535679-URG-A-0909 sub-base. Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes: Nothing * 24" clearance in front and 18" on side recommended for service access. Johnson Controls Unitary Products All furnaces approved for alcove and attic installation.
  • Page 2 MOST COMMON INSTALLATION CONFIGURATIONS (MORE OPTIONS AVAILABLE WITH INDUCER ROTATION, WHICH IS COVERED IN THE INSTALLATION MANUAL) Furnace is multi-position and may be installed in any of the configurations shown. Inducer blower may be rotated 90° either way to vent through casing side, as shown below. These are Category I units and the vent system must be installed in accordance with latest edition of the National Fuel Gas Code, Z223.1/NFPA 54, or in Canada, CSA B149.1.

This manual is also suitable for:

Tplc080b12mp12cTplc100c20mp12cTplc100c16mp12cTplc120c20mp12cTplc080c16mp12cYplc060a12mp12c ... Show all