681292-UIM-A-0211
THERMOSTAT
*DN22U00124
C
24 – Volt Common
Y1
First Stage Compressor
R
24 – Volt Hot
(Heat XFMR)
G
Fan
E/W1
First Stage Heat
W2
Second Stage Heat
R
24 – Volt Hot
(Cool XFMR)
Y2
Second Stage
Compressor
2
Connection of the "C"
terminal, 24-volt common
is optional when used with
batteries
Thermostat Installer Setup
1-System Type-must
be set to 8-1 Heat/2 Cool
Conventional
Thermostat Installer Setup
15-Compressor Protection
must be set to 5
2
FIGURE 22: Thermostat Chart - Two Stage Air Conditioner – Variable Speed Modulating Furnace
16
THERMOSTAT
*PP32U70124
C
24 – Volt Common
Y1
First Stage Compressor
R
24 – Volt Hot
(Heat XFMR)
G
Fan
E/W1
Emergency Heat
AUX
Auxiliary Heat
R
24 – Volt Hot
(Cool XFMR)
Y2
Second Stage
Compressor
External Humidistat
(Optional)
Open on Humidity Rise
Connection of the "C"
terminal, 24-volt common
is optional when used with
batteries
Thermostat Installer Setup
0170-System Type-must
be set to 10-1 Heat/2 Cool
Multistage Conventional
Part Number:
S1-2HU16700124
ID MODELS
TP9C
YP9C
CP9C
LP9C
MODULATING
FURNACE
MODULATING
1
FURNACE CONTROL
C
24 – Volt Common
Y1
Single
Stage Compressor
R
24 – Volt Hot
G
Fan
W
Modulating Heat
Y/Y2
Second or Full
Stage Compressor
O
Reversing Valve
Energized in Cool
LO COMP
Single Stage
Compressor (OUT)
HI COMP
Second Stage
Compressor (OUT)
DHUM
Dehumidification-
Open on Humidity Rise
Move HUMIDISTAT
jumper to "YES"
if humidistat is to be used.
Part Numbers:
1
SAP =
Legacy

Johnson Controls Unitary Products

TWO STAGE
AIR
CONDITIONER
C
24 – Volt Common
Y1
First Stage Compressor
R
24 – Volt Hot
Y2
Second Stage
Compressor