Thermostat Chart - Two Stage Air Conditioner - Variable Speed Or Psc Modulating Furnace - Johnson Controls TM8M/TMLM*MP Installation Manual

Residential gas furnace with psc motor (80% modulating multi-position / low nox)
Table of Contents

Advertisement

368261-UIM-B-1008
THERMOSTAT
*DN22U00124
C
24 – Volt Common
Y1
First Stage Compressor
R
24 – Volt Hot
(Heat XFMR)
G
Fan
E/W1
First Stage Heat
W2
Second Stage Heat
R
24 – Volt Hot
(Cool XFMR)
Y2
Second Stage
Compressor
2
Connection of the "C"
terminal, 24-volt common
is optional when used with
batteries
Thermostat Installer Setup
1-System Type-must
be set to 6-2 Heat/2 Cool
Multistage Conventional
Thermostat Installer Setup
15-Compressor Protection
-must be set to 5
2
FIGURE 20: Thermostat Chart - Two Stage Air Conditioner – Variable Speed or PSC Modulating Furnace
14
THERMOSTAT
*PP32U70124
C
24 – Volt Common
Y1
First Stage Compressor
R
24 – Volt Hot
(Heat XFMR)
G
Fan
E/W1
Emergency Heat
AUX
Auxiliary Heat
R
24 – Volt Hot
(Cool XFMR)
Y2
Second Stage
Compressor
External Humidistat
(Optional)
Open on Humidity Rise
Connection of the "C"
terminal, 24-Volt common
is optional when used with
batteries
Thermostat Installer Setup
0170-System Type-must
be set to 8-2 Heat/2 Cool
Multistage Conventional
Part Number:
S1-2HU16700124
ID MODELS
TM(8,L)M
YM(8,L)M
CM(8,L)M
LM(8,L)M
MODULATING
FURNACE
MODULATING
1
FURNACE CONTROL
C
24 – Volt Common
Y1
Single
Stage Compressor
R
24 – Volt Hot
G
Fan
W
Modulating Heat
Y/Y2
Second or Full
Stage Compressor
O
Reversing Valve
Energized in Cool
LO COMP
Single Stage
Compressor (OUT)
HI COMP
Second Stage
Compressor (OUT)
DHUM
Dehumidification-
Open on Humidity Rise
Move HUMIDISTAT
jumper to "YES"
if humidistat is to be used.
Part Numbers:
1
SAP =
Legacy
Johnson Controls Unitary Products
TWO STAGE
AIR
CONDITIONER
C
24 – Volt Common
Y1
First Stage Compressor
R
24 – Volt Hot
Y2
Second Stage
Compressor

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents