Temperatures Available with a Controller
The water heater can deliver water at only one temperature se ng at a me. The available temperatures are
provided below. A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water.
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the "On/Off" bu on
for 5 seconds while the water heater is OFF.
V75i/e, V65i/e
Celsius °C
*
Temperature se ngs from 125‐140 °F (52‐60 °C) are available by se ng switch 6 to ON in the SW1 Dip
switch (tan switches). These models have a default maximum temperature of 120° F (49° C) and an op on
(switch 6) to increase the maximum temperature to 140 °F (60 °C).
** These se ngs require the MCC‐91 controller. When the MCC‐91 controller is connected, these higher
temperatures are available on all controller models in the system.
If an MCC‐91 controller is used in a residen al dwelling for a hydronics applica on, a mixing valve must also
be installed to limit the potable hot water temperature to a safe temperature. Water temperatures over
125° F (52°C) can cause severe burns or scalding. Refer to the Danger Alert on water temperatures. Rinnai
shall not, in any event, be liable for damages resul ng from such misuse or misapplica on.
WARNING
These temperatures are sugges ons only:
Temperature Op ons Without a Temperature Controller
The default temperature se ng for this appliance installed without a temperature controller is 120° F (49° C). If
desired, the temperature se ng can be changed to 140° F (60° C) by adjustment of a switch.
In the SW1 Dip switch (tan switches), set switch 5 to ON to obtain 140° F water temperature se ng. Set switch
5 to OFF (default) to obtain 120° F water temperature se ng. If a temperature controller is installed, then
switch 5 has no effect on temperature se ngs.
Se ng Controller to Mute
On the MC‐91‐2 to eliminate the beeps when keys are pressed or to turn the beeps back on, press and hold both
the up and down bu ons un l a beep is heard (approximately 5 seconds).
Locking the Controller
The MC‐91‐2 controller can be locked by pressing the Priority bu on and the up bu on together for 5 seconds.
A beep will sound confirming that the controller is locked. The display will alternately show "LOC", the
temperature se ng, and a diagnos c code if one has been ac vated. All of the controllers in the system are
also locked.
To unlock the controller press the Priority bu on and the up bu on together for 5 seconds.
32
Temperature Se ngs Available (Fahrenheit °F)
98 100 102 104 106 108 110 115 120
37
38
39
40
DO NOT adjust the other switches unless specifically instructed to do so.
•
•
•
41
42
43
46
Kitchen 120 °F (49° C)
Shower 98 ‐ 110 °F (37 ‐ 43 °C)
Bath Fill 102 ‐ 110 °F (39 ‐ 43 °C)
Value Series Manual
125
130
135
140
*
*
*
49
52
54
57 60
150
160
*
**
**
66
71