READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS WATER HEATER.
This manual provides informa on on the installa on, opera on, and maintenance of the water heater. For proper
opera on and safety, it is important to follow the instruc ons and adhere to the safety precau ons.
A licensed professional must install the water heater according to the exact instruc ons on pages 4-30.
The consumer must read the en re manual to properly operate the water heater and to have regular maintenance
performed.
WARNING
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instruc ons.
If you cannot reach your gas supplier, call the fire department.
— Installa on and service must be performed by a licensed professional.
This en re manual must be le for the consumer. The consumer must read and
refer to this manual for proper opera on and to maintain the water heater.
REU-VC2528FFUD-US(A)
REU-VC2528FFUD-US(A)
ANS Z21.10.3 ● CSA 4.3
If the informa on in these instruc ons is not followed exactly, a fire or explosion
may result causing property damage, personal injury, or death.
Direct Vent Tankless Water
Heater Installa on and
Opera on Manual

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai RL75i

  • Page 1 Direct Vent Tankless Water Heater Installa on and Opera on Manual FOR INDOOR APPLICATIONS ONLY RL75i ..... REU-VC2528FFUD-US REU-VC2528FFUD-US(A) RLX94i ....REU-VC2737FFUD-US RL94i ..... REU-VC2837FFUD-US FOR OUTDOOR APPLICATIONS ONLY RL75e ....REU-VC2528WD-US REU-VC2528FFUD-US(A) RL94e ....REU-VC2837WD-US ANS Z21.10.3 ● CSA 4.3 READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS WATER HEATER.
  • Page 2: Table Of Contents

    If you have any ques ons or feel that the manual is incomplete contact Rinnai at 1-800-621-9419 Important Safety Informa on Safety Defini ons...
  • Page 3: Safety Behaviors And Prac Ces For The Consumer And Installer

    Safety Behaviors and Prac ces for the Consumer and Installer WARNING Use only your hand to push in or turn the gas Before opera ng, smell all around the appliance area for gas. Be sure to smell next to the floor control knob.
  • Page 4: Installa On Instruc Ons

    A licensed professional must install the appliance, DO NOT inspect it, and leak test it before use. The warranty Do not install the RL75i, RL94i, or the RLX94i will be voided due to any improper installa on. outdoors. The installer should have skills such as: Do not install the RL75e or the RL94e indoors.
  • Page 5: Prepare For Installa On

    General Instruc ons (con nued) Prepare for installa on The appliance must be isolated from the gas supply Parts included piping system by closing its individual manual shutoff valve during any pressure tes ng of the gas Tankless water heater supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa) (13.84 in W.C.).
  • Page 6: Determine Installa On Loca On

    Install as far away as possible from any air inlet unit is set at a high temperature. vents. Corrosive fumes may be released through Rinnai offers Southeastern Filtra on’s “ScaleCu er these vents when air is not being brought in Water Condi oning System” that offers superior lime through them.
  • Page 7 Terminal Clearances For indoor models, you must install a vent termina on to bring in combus on air and expel exhaust. TERMINATION INSIDE CORNER DETAIL Clearance in Ref. A also applies to anticipated snow line SNOW FIXED CLOSED OPERABLE AIR SUPPLY INLET FIXED VENT TERMINAL CLOSED...
  • Page 8 Addi onal clearances - RL75i, RL94i, RLX94i Check to determine whether local codes supersede 60" (1.52 m) these clearances. between terminals at Avoid termina on loca ons near a dryer vent. different levels Avoid termina on loca ons near commercial cooking exhaust.
  • Page 9 Addi onal clearances RL75e, RL94e Local codes supersede these clearances. Avoid termina on loca ons near a dryer vent. Avoid termina on loca ons near commercial cooking exhaust. Avoid termina on loca ons near any air inlets. (0.91 m) to ven lated or unven lated 36"...
  • Page 10 Unit clearances Indoor models: RL75i, RL94i, RLX94i Outdoor models: RL75e, RL94e to Non- to Non- to Combus bles to Combus bles Combus bles Combus bles inches (mm) inches (mm) inches (mm) inches (mm) Top of Heater 6 * (152) 2 *(51)
  • Page 11: Freeze Protec On And Winteriza On

    Maximum vent length Freeze Protec on (indoor models only) Make sure that in case of freezing weather that the water heater and its water lines are protected to 1. Determine the number of 90 degree elbows in prevent freezing. Damage due to freezing is not the vent system.
  • Page 12: Checklist To Determine Installa On Loca On

    Mount to Wall Checklist to Determine Installa on Loca on □ The water heater is not exposed to corrosive compounds in the air. □ The water heater loca on complies with the wall installa on clearances. brackets □ For indoor models, the planned ven ng will not exceed the maximum length for the number of elbows used.
  • Page 13: Installa On Of Ven Ng (Indoor Models Only)

    If it becomes necessary to access an enclosed vent cer fied and listed with the water heater model. system for service or repairs, Rinnai is not responsible The vent system must vent directly to the outside for any costs or difficul es in accessing the vent of the building and use outside air for combus on.
  • Page 14 Flue Installa on (indoor models only) Install the ven ng termina on according to the diagrams and instruc ons below. Horizontal Termina on without using the Condensate Collector WARNING If the condensate collector is not used, the drain pipe must * The condensate collector must be used in be capped to prevent exhaust gases and condensate from horizontal termina ons if a ver cal rise in...
  • Page 15: Condensate (Indoor Models Only)

    Condensate (indoor models only) INFORMATION Condensate can form in the vent of high efficiency direct vent appliances. Without proper drainage, A condensate trap is available, P/N 222053. condensate will damage the heat exchanger. Regions of cold climate will create more To prevent condensate damage, follow these condensate in the vent system.
  • Page 16: Installa On Of Plumbing

    Isola on valves are included with this water heater. Do not place any other type valve or shutoff device Rinnai strongly recommends the installa on of between the relief valve and the water heater. isola on valves on the cold and hot water lines...
  • Page 17 Isola on Valves and Pressure Relief Valve The isola on valves provide the ability to isolate the water heater from the structure’s plumbing and allow quick access to flush the heat exchanger. Check with local codes to determine if a pressure and temperature relief valve is required.
  • Page 18 Piping Diagram for Basic Installa on Rinnai Water Heater Rinnai Equipment List Rinnai Water Heaters RIK-KIT (Optional) (3/4" Fittings Include: 2 Unions, 2 Ball Valves, 2 Drain Valves and 1 Pressure Relief Valve.) 3/4" Hot Water Supply Line For Building Fixtures This is not an engineered drawing.
  • Page 19: Checklist For Plumbing

    Minimum/Maximum water pressure is Use approved connectors to connect the unit to 20-150 psi. Rinnai recommends 30-80 psi for the gas line. Purge the gas line of any debris maximum performance. before connec on to the water heater.
  • Page 20 Any compound used on the threaded joint of the Pipe Sizing Table - Natural Gas gas piping shall be a type that resists the ac on of Schedule 40 Metallic Pipe liquefied petroleum gas (propane / LPG). Inlet Pressure: less than 2 psi (55 inches W.C.) The gas supply line shall be gas ght, sized, and so Pressure Drop: 0.3 inches W.C.
  • Page 21: Connect Electricity

    Connect Electricity Adjustment for High Al tude Installa ons WARNING On the SW1 DIP switch (tan switches), set switches 2 Do not use an extension cord or an adapter plug with and 3 to the values shown in table below for your this appliance.
  • Page 22: Installa On Of Temperature Controller

    120 volt poten al next to the temperature Controllers cannot be wired in series. controller connec ons inside the unit. Do not connect the temperature controller to the Maximum 4 Controllers Rinnai 120VAC terminals provided for the op onal solenoid Water drain valves. Heater Indoor models have their controller built into the front panel.
  • Page 23 Moun ng the controller 1. Make three holes in the wall as shown. Outline of Remote securing screw 1-21/32" wiring hole 3-5/16" securing screw 2. Run the cable between the controller and the water heater or the controller and another controller.
  • Page 24: Final Checklist

    Final Checklist □ □ Check the gas lines and connec ons for leaks. The water heater is not subject to corrosive □ compounds in the air. Confirm that the gas inlet pressure is within □ limits. The water supply does not contain chemicals or □...
  • Page 25: Technical Data

    Technical Data Specifica ons RL75i RLX94i RL94i RL75e RL94e Minimum Gas Consump on Btu/h 10,300 Maximum Gas Consump on Btu/h 180,000 192,000 199,000 180,000 199,000 0.26 - 7.5 GPM 0.26 - 9.8 GPM 0.26 - 9.8 GPM 0.26 - 7.5 GPM 0.26 - 9.8 GPM...
  • Page 26: Dimensions

    Dimensions Inches (millimeters) RL75i, RL94i, RLX94i 9.27 (235.5) 14.04 (356.6) 0.4~1.8(10~45) Variable 5.05 (128.1) DIMENSION Inches (mm) DIMENSION Inches (mm) A (GAS) 1.31 (33.2) 4.33 (110) A (COLD) 1.93 (49) 2.89 (73.3) A (HOT) 1.35 (34.4) 1.85 (47) 4.21 (106.9) 3.44 (87.3)
  • Page 27: Pressure Drop And Water Flow Curves

    Pressure Drop Curve RL75 RL94, RLX94 Water Flow (gpm) Water Flow Curve 10.0 RL94 RLX94i RL75 delta T - Temperature Rise (° F) VC Series Manual...
  • Page 28: Ladder Diagram

    Ladder Diagram VC Series Manual...
  • Page 29: Recircula On Mode

    Recircula on Mode recommenda ons. The Rinnai water heater has the ability to control a recircula on pump. Two modes are available, 4. Adjust the dip switch by moving the 4th switch in Economy and Comfort, which recirculate the water in the whie set of switches (SW2) to ON.
  • Page 30 Sequence of Opera on Rinnai Typical Pump ON Intervals* DIP switches (SW2 - white switches, #4, #8) should be Temperature set correctly for recircula on and mode. The Rinnai Se ng water heater should be turned on. Economy Comfort Mode Mode °F...
  • Page 31: Opera On Instruc Ons

    RL94e ....REU-VC2837WD-US Important Facts about your Water Heater Thank you for purchasing a Rinnai Tankless Water Heater. For proper opera on and safety, it is important to follow the instruc ons and adhere to the safety precau ons. Read all of the instruc ons and the warranty thoroughly before opera ng this water heater. Keep this manual in a safe place.
  • Page 32: Consumer Opera On Guidelines For The Safe Opera On Of Your Water Heater

    Consumer Opera on Guidelines for the Safe Opera on of your Water Heater FOR YOUR SAFETY READ BEFORE OPERATING WARNING If you do not follow these instruc ons exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. A.
  • Page 33: How To Use The Temperature Controller

    floor. heat exchanger flushed regularly. Rinnai provides a “Scale Control System” that offers superior lime Keep the area around the appliance clear and free...
  • Page 34: How To Set The Temperature

    How to Set the Temperature This water heater requires a minimum flow rate to operate. This rate can be found on the specifica on page in this manual. In some cases when you are not ge ng hot water or if the water alternates between hot and cold, it is due to the water flow being below or close to the minimum flow rate.
  • Page 35 To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off” bu on for 5 seconds while the water heater is OFF. Temperature Se ngs Available (Fahrenheit °F) RL75i, RL75e 98 100 102 104 106 108 110 115 120 RL94i, RLX94i, 185** Celsius °C...
  • Page 36: Diagnos C Codes

    Temperature Op ons Without a Temperature Controller The default temperature se ng for this appliance installed without a temperature controller is 120° F (49° C). If desired, the temperature se ng can be changed to 140° F (60° C) by adjustment of a switch. In the SW1 Dip switch (tan switches), set switch 5 to ON to obtain 140°...
  • Page 37 Diagnos c Codes and Remedies Some of the checks below should be done by a licensed professional. Consumers WARNING should never a empt any ac on that they are not qualified to perform. Code Defini on Remedy Power interrup on during Bath Fill (Water will not flow when Turn off...
  • Page 38 LC2,…) Off bu on on the temperature controller 5 mes. Repeated LC codes will eventually lockout “LC”) the water heater. Please call Rinnai technical department. Maintenance has been Indicates a licensed professional performed maintenance or corrected an issue. performed Clean inlet water supply filter.
  • Page 39: Required Maintenance

    Required Maintenance The appliance and vent system must be inspected annually by a licensed professional. Repairs and maintenance should be performed by a licensed professional. The licensed professional must verify proper opera on a er servicing. WARNING To protect yourself from harm, before performing maintenance: Turn off...
  • Page 40 drain down solenoid valves be purchased and WARNING installed that will automa cally drain the unit if power is lost. These are available in a kit, Tes ng the pressure relief valve should only be 104000059. (The condensate trap is not affected performed by a licensed professional.
  • Page 41: Flushing The Heat Exchanger

    An LC0~LC9 or “00” diagnos c code indicates the unit is beginning to lime up and must be flushed. Failure to flush the appliance will cause damage to the heat exchanger. Damage caused by lime build-up is not covered by the unit’s warranty. Rinnai strongly recommends installa on of isola on valves to allow for flushing of the heat exchanger.
  • Page 42: Manual Draining Of The Water Heater

    Manual Draining of the Water Heater To avoid burns, wait un l the equipment cools down before draining the water. The WARNING water in the appliance will remain hot a er it is turned off. If the water heater is not going to be used during a period of possible freezing weather, it is recommended that the water inside the water heater be drained.
  • Page 43: State Regula Ons

    State Regula ons NOTICE BEFORE INSTALLATION This direct-vent appliance must be installed by a licensed professional. If you are not properly trained, you must not install this unit. IMPORTANT: In the State of Massachuse s (248 CMR 4.00 & 5.00) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residen al purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termina on is less than seven (7) feet above finished grade in the area of the ven ng, including but not limited...
  • Page 44: Replacement Parts

    Replacement Parts The Technical Sheet that is located inside the front cover of the water heater contains a complete illustrated parts list. Tech Sheet Gas Control Assembly Electrode / Flame Rod Gas Control Assembly Electrode / Flame Rod Kit 116, 117 Fan Assembly / Motor Heat Exchanger Water Flow Servo &...
  • Page 45: Consumer Warranty

    A mer added to a standard recircula ng pump is not considered as on-demand. [2] Period of coverage is reduced to 5 years from date of purchase if the Rinnai water heater temperature se ng exceeds 160° F (71°C).
  • Page 46 Limita on on warran es No one is authorized to make any other warran es on behalf of Rinnai America Corpora on. Except as expressly provided herein, there are no other warran es, expressed or implied, including, but not limited to warran es of merchantability or fitness for a par cular purpose, which extend beyond the descrip on of the warranty herein.
  • Page 47 RL75, RL94, and RLX94i if you register within 30 days of purchase of your unit. Products not registered will s ll be cov- ered under the Rinnai standard product limited warranty as provided in the Installa on and Opera on manual which comes with this product.
  • Page 48: French Version

    Chauffe-eau sans réservoir à ven la on directe Manuel d’installa on et d’u lisa on POUR DES APPLICATIONS EN INTÉRIEUR UNIQUEMENT RL75i ..... REU-VC2528FFUD-US REU-VC2528FFUD-US(A) RLX94i ....REU-VC2737FFUD-US RL94i ..... REU-VC2837FFUD-US POUR DES APPLICATIONS EN EXTÉRIEUR UNIQUEMENT RL75e ....REU-VC2528WD-US REU-VC2528FFUD-US(A) RL94e ....
  • Page 49 Installa on de contrôleur de température ..... 69 AVIS : Rinnai partage parfois des informa ons de contact de clients avec des entreprises qu’il es me pouvoir fournir des produits ou services qui peuvent vous être u les. En communicant ces informa ons, vous donnez votre accord pour que nous vous communiquions vos informa ons de contact dans ce but.
  • Page 50: A Tudes Et Pra Ques De Sécurité Pour Le Consommateur Et L'installateur

    A tudes et pra ques de sécurité pour le consommateur et l’installateur AVERTISSEMENT Avant la mise en œuvre, reniflez tout autour de la N’u lisez que votre main pour appuyer sur le bouton zone de l’appareil pour détecter une odeur de gaz. Ne de commande de gaz ou l’enfoncer.
  • Page 51: Instruc Ons D'installa On

    Un installateur professionnel agréé qui doit installer À ÉVITER l’appareil, l’inspecter, et tester des fuites éventuelles N’installez pas de chauffe-eau RL75i, RL94i ou RLX94i avant son u lisa on. La garan e pourrait être annulée du à l’extérieur. fait d’une installa on incorrecte.
  • Page 52: Prépara On Pour L'installa On

    Instruc ons générales (Suite) Prépara on pour l’installa on L’appareil devra être isolé du système de conduite Pièces incluses d’alimenta on en gaz en fermant sa vanne de coupure manuelle d’alimenta on durant tout test de Chauffe-eau sans réservoir pression de ce système en dessous de 1/2 psi (3,5 kPa ou13,84 pouces de hauteur de colonne d’eau).
  • Page 53: Détermina On De L'emplacement De L'installa On

    élevée. d’admission d’air. Des fumées corrosives peuvent être Rinnai propose le “Système de condi onnement d’eau libérées par ces évents quand l’air n’est pas aspiré ScaleCu er” de Southeastern Filtra on qui permet une dedans.
  • Page 54 Dégagements à la terminaison Pour les modèles d’intérieur, vous devez installer une terminaison de ven la on pour faire entrer de l’air de combus on et dégager les gaz d’échappement. TERMINAISON TERMINATION INSIDE DÉTAIL D’ANGLE CORNER DETAIL RENTRANT Le dégagement Clearance in en référence A Ref.
  • Page 55 Dégagements addi onnels - RL75i, RL94i, RLX94 Contrôlez si des réglementa ons locales sont plus exigeantes 60" (1,52 m) entre que ces valeurs de dégagements. des terminaisons à des niveaux Évitez de posi onner des terminaisons près d'une différents ven la on d’un déshydrateur Évitez de posi onner des terminaisons près d’une...
  • Page 56 Dégagements addi onnels - RL75e, RL94e Les normes locales ont la préséance sur ces recommanda ons. Évitez de posi onner des terminaisons près d'une ven la on d’un déshydrateur. Évitez de posi onner des terminaisons près d’une évacua on de cuisine commerciale. Évitez de posi onner des terminaisons près de n’importe quelles bouches d’admission d’air.
  • Page 57 Vers le côté Vers l’avant Vers l’avant Vers le sol/le bas Vers le sol/le bas Modèles d’intérieur : RL75i, RL94i, RLX94i Modèles d’extérieur : RL75e, RL94e Par rapport à des Par rapport à des Par rapport à des Par rapport à des...
  • Page 58 Longueur maximale de ven la on Protec on contre le gel (modèles d’intérieur uniquement) Assurez-vous que par temps très froid le chauffe-eau et ses conduites d'eau sont protégées pour éviter le gel. Les dommages dus au gel ne sont pas couverts par la garan e. Déterminez le nombre de coudes à...
  • Page 59: Liste De Contrôle Pour Choisir L'emplacement De L'installa On

    Montage mural Liste de contrôle pour choisir l’emplacement de l’installa on □ Le chauffe-eau n’est pas exposé à des composés corrosifs dans l’air. □ L’emplacement du chauffe-eau permet de respecter Supports les dégagements. d’installa on murale □ Pour les modèles d’intérieur, la ven la on prévue ne dépassera pas la longueur maximale en fonc on du nombre de coudes u lisé.
  • Page 60: Installa On De Ven La On (Modèles D'intérieur Uniquement)

    Le système de ven la on doit donner directement sur de répara on, Rinnai n’est pas responsable des coûts ou l’extérieur du bâ ment et u liser de l’air extérieur pour des difficultés pour y accéder.
  • Page 61 Installa on d’évacua on des gaz de combus on (modèles d’intérieur uniquement) Installez la terminaison de ven la on en fonc on des schémas et des instruc ons qui suivent. Installa on horizontale sans u liser de collecteur de condensats AVERTISSEMENT Si le collecteur de condensats n’est pas u lisé, le tube de drainage * Le collecteur de condensats doit être u lisé...
  • Page 62: Condensats (Modèles D'intérieur Uniquement)

    Condensats (modèles d’intérieur uniquement) INFORMATIONS Des condensats peuvent se former dans la ven la on d’appareils à ven la on directe de grande efficacité. Sans Un piège à condensat est disponible sous le N° de pièce un drainage correct les condensats endommageraient 222053.
  • Page 63: Installa On De La Plomberie

    Ne placez aucun type de vanne ou de disposi f de Des vannes d’isolement sont incluses sur ce chauffe-eau. coupure entre la soupape de décharge et le chauffe- Rinnai recommande fortement l’installa on de vannes eau. d’isolement sur les conduites d’eau chaude et d’eau froide, car elles donnent la possibilité...
  • Page 64 Vannes d’isolement et soupapes de décharge Les vannes d’isolement procurent la capacité d’isoler le chauffe-eau de la plomberie de la structure et de perme re un accès rapide pour rincer l’échangeur thermique. Contrôlez dans les normes locales si une soupape de décharge déclenchée sur pression et température est nécessaire.
  • Page 65 Schéma de tuyauterie pour installa on de base Rinnai Rinnai Water Heater Water Heater Chauffe-eau Rinnai Rinnai Equipment List Equipment List Rinnai Rinnai Water Heaters Water Heaters RIK-KIT (Optional) RIK-KIT (Optional) (3/4" Fittings Include: (3/4" Fittings Include: 2 Unions, 2 Ball Valves,...
  • Page 66: Liste De Contrôle Pour La Plomberie

    U lisez des connecteurs approuvés pour brancher le chauffe-eau. La pression d’eau minimale/maximale chauffe-eau sur la conduite de gaz. Purgez la conduite doit être de 20-150 psi. Rinnai recommande 30-80 psi de gaz de tous débris avant son branchement sur le pour une performance maximale.
  • Page 67 Tout composé u lisé sur un joint fileté de tuyauterie de Tableau de calibrage de tube – Gaz naturel gaz doit être d’un type qui résiste à l’ac on du gaz de Tube métallique qualité 40 pétrole liquéfié (propane / LPG). Pression d’entrée : Moins de 2 psi (55 pouces de La conduite d’alimenta on au gaz doit être étanche, de hauteur de colonne d’eau)
  • Page 68: Raccordement De L'électricité

    Raccordement de l’électricité Réglage pour installa ons à forte al tude AVERTISSEMENT Sur le bloc SW1 de micro-commutateurs DIP (bronze), N’u lisez pas de cordon rallonge, ni d’adaptateur de prise passez les micro-commutateurs 2 et 3 sur les posi ons avec cet appareil.
  • Page 69: Installa On De Contrôleur De Température

    Ne branchez surtout pas le contrôleur de température sur Maximum 4 contrôleurs Maximum 4 Controllers les bornes de 120 V prévues pour les électrovannes Chauffe- Rinnai op onnelles de drainage. Water Heater Rinnai Des modèles ont leur contrôleur intégré dans le panneau frontal.
  • Page 70 Montage du contrôleur Faites trois trous dans le mur comme c’est montré. Contour de la Outline of Remote télécommande Vis de fixa on securing screw 1-21/32" Trou pour câblage wiring hole 3-5/16" securing screw Vis de fixa on Faites passer le câble entre le contrôleur et le chauffe- eau, ou entre le contrôleur et un autre contrôleur.
  • Page 71: Liste De Contrôle Final

    Liste de contrôle final □ □ Contrôlez les conduites et raccordements de gaz pour Le chauffe-eau n’est pas exposé à des composés l’absence de fuites. corrosifs dans l’air. □ □ Confirmez que la pression d’entrée du gaz est dans les L’eau d’alimenta on ne con ent pas de produits limites.
  • Page 72: Données Techniques

    Données techniques Spécifica ons RL75i RLX94i RL94i RL75e RL94e Consomma on min. de gaz en Btu/h 10 300 Consomma on max. de gaz en Btu/h 192 000 199 000 180 000 180 000 199 000 Capacité en eau chaude 0,26 – 7,5 GPM 0,26 –...
  • Page 73: Dimensions

    Dimensions Pouces (millimètres) RL75i, RL94i, RLX94i 9,27 (235,5) 14,04 (356,6) 0,4~1,8 (10~45) Variable 5,05 (128,1) ENTRÉE D’EAU FROIDE CONNEXION DE GAZ SORTIE D’EAU CHAUDE DIMENSION Pouces (mm) DIMENSION Pouces (mm) A (GAZ) 1,31 (33,2) 4,33 (110) A (FROID) 1,93 (49) 2,89 (73.3)
  • Page 74: Courbes De Chute De Pression Et De Flux D'eau

    Courbe de chute de pression RL75 RL94, RLX94 Débit d’eau (gallons/minute) Courbe de débit d’eau 10.0 RL94 RLX94i RL75 Delta T – Montée en température (°F) Manuel de Série VC...
  • Page 75: Diagramme En Escalier

    Diagramme en escalier PHASE NEUTRE POMPE RELAIS 3 FUSIBLE 10A INTERRUPTEUR CHAUFFAGE ANTIGEL DÉTECTEUR DE GEL RELAIS 2 DÉCHARGEUR DE FOUDRE VARISTANCE VARISTANCE ALLUMAGE RELAIS 1 TERRE ALIENTATION À DÉCOUPAGE 170 V CC 12,6 V CC 40 V CC 5 V CC 0~50 V CC CAPTEUR DE ÉLECTROVANNE...
  • Page 76: Mode Recircula On

    D’EAU FROIDE (Minimum 3/4") Pour plus d’informa ons sur le calibre de pompe, référez- CLAPET ANTI- vous au Guide Rinnai Circ-Logic™ ou à la sec on “Calibre de RETOUR RACCORDEMEN pompe pour circula on” dans le manuel Rinnai de RÉSERVOIR À...
  • Page 77 Les micro-commutateurs DIP (N° 4 et 8 du bloc blanc SW2) Réglage de nement de la pompe * doivent être posi onnés correctement pour le mode de consigne de recircula on. Le chauffe-eau Rinnai doit être mis en température Mode marche. Mode de con- du Rinnai en °F...
  • Page 78: Instruc Ons D'u Lisa On

    AVIS : Rinnai partage parfois des informa ons de contact de clients avec des entreprises qu’il es me pouvoir fournir des produits ou services qui peuvent vous être u les. En communicant ces informa ons, vous donnez votre accord pour que nous communiquions vos informa ons de contact dans ce but.
  • Page 79: Consignes À L'opérateur Pour Un Fonc Onnement Sûr De Son Chauffe-Eau

    Consignes à l’opérateur pour un fonc onnement sûr de son chauffe-eau POUR VOTRE SÉCURITÉ LISEZ CECI AVANT DE COMMENCER AVERTISSEMENT Si vous ne suivez pas exactement ces instruc ons, il peut en résulter un départ d’incendie ou une explosion entraînant des dégâts matériels et blessures pouvant être fatales.
  • Page 80: Mode D'emploi Du Contrôleur De Température

    Rinnai propose le “Système de condi onnement d’eau ScaleCu er” de Southeastern Gardez la zone autour de l’appareil dégagée et Filtra on qui permet une préven on supérieure du...
  • Page 81: Fixa On De La Température

    Fixa on de la température Le chauffe-eau nécessite un minimum d’écoulement d’eau pour fonc onner. Ce seuil peut être trouvé sur la page de spécifica ons dans ce manuel. Dans certains cas, quand vous n’obtenez pas d’eau chaude ou si l’eau passe de chaude à froide, cela peut venir de ce que l’écoulement d’eau est en-dessous ou trop proche du seuil minimal d’écoulement.
  • Page 82 Pour changer l’échelle des températures et passer de Celsius à Fahrenheit ou vice-versa, appuyez sur le bouton On/Off et maintenez-le enfoncé pendant 5 secondes pendant un arrêt du chauffe-eau. Réglages de température disponibles (Fahrenheit °F) RL75i, RL75e 98 100 102 104 106 108 110 115 120 RL94i, RLX94i,...
  • Page 83: Codes De Diagnos C

    Op ons de température sans contrôleur de température Le réglage de température par défaut de cet appareil installé sans contrôleur de température est de 120°F (49 °C). Si on le souhaite ce réglage de température peut être changé pour 140°F (60 °C) en jouant sur un micro-commutateur. Sur le bloc bronze SW1, passez le micro-commutateur N°...
  • Page 84 Diagnos c Codes and Remedies Certains de contrôles ci-dessous ne doivent être effectués que par un professionnel agréé. AVERTISSEMENT Les simples consommateurs ne doivent jamais tenter une interven on qu’ils ne sont pas qualifiés pour effectuer. Code Défini on Remède Interrup on du secteur durant un remplissage de baignoire (l’eau ne Fermez tous les robinets d’eau chaude.
  • Page 85 LC2,…) subs tué pour “LC”) éventuellement verrouiller le chauffe-eau. Veuillez appeler le service technique chez Rinnai. Un entre en a été effectué Indique d’un professionnel agréé a effectué une interven on ou corrigé un problème. Ne oyez le filtre d’arrivée d’eau.
  • Page 86: Entre En Nécessaire

    Entre en nécessaire L’appareil doit être inspecté annuellement par un professionnel agréé. Installa on et interven ons de service doivent être effectuées par un professionnel agréé. Ce professionnel agréé doit vérifier le bon fonc onnement après une interven on. AVERTISSEMENT Pour vous protéger de toute a einte, avant d’effectuer une interven on d’entre en : Coupez l’alimenta on électrique en débranchant la fiche du cordon secteur ou en coupant le secteur au disjoncteur du circuit.
  • Page 87: Protec On Contre Le Gel Et Prépara On

    Des électrovannes de vidange soient achetées et AVERTISSEMENT installées pour vider automa quement le chauffe-eau en cas de coupure d’alimenta on secteur. Elles sont Le test de soupapes de décharge ne doit être fait que par proposées dans un kit, N° de pièce 104000059 (Le un professionnel agréé.
  • Page 88: Rinçage De L'échangeur Thermique

    Un code de diagnos c LC0~LC9 ou “00” indique que le chauffe-eau commence à s’entartrer et doit être rincé. Ne pas le faire endommagerait son échangeur thermique. Des dommages causés par une accumula on de tartre ne sont pas couverts par la garan e de l’appareil. Rinnai recommande fortement l’installa on de vannes d’isolement pour perme re un rinçage de l’échangeur thermique.
  • Page 89: Vidange Manuelle Du Chauffe-Eau

    Vidange manuelle du chauffe-eau Pour éviter des brûlures, a endez que l’équipement ait refroidi avant de vidanger l’eau. AVERTISSEMENT L’eau restera longtemps chaude dans l’appareil après son arrêt. Si le chauffe-eau ne doit pas être u lisé durant une période où il pourrait geler, il est recommandé que l’eau à l’intérieur soit vidangée.
  • Page 90: Pièces De Rechange

    Pièces de rechange La fiche technique, qui est située sur la face intérieure du couvercle avant du chauffe-eau, con ent une liste complète illustrée des pièces. N° d’ar cle de la Ensemble de commande Kit d’électrode/ électrode fiche technique de gaz de gaz Ensemble de commande de gaz Kit d’électrode/ électrode de...
  • Page 91: Garan E Du Consommateur

    à la demande. [2] La période de couverture est réduite à 5 ans à compter de la date d’achat si le réglage du point de consigne de température du chauffe-eau Rinnai dépasse 160°F (71 °C).
  • Page 92 Limita ons des garan es Personne n’est autorisé à exprimer toute autre garan e au nom de la Rinnai America Corpora on. Sauf ce qui est formulé expressément ici, il n’y a pas d’autres garan es, explicites ou implicites, incluant sans y être limité les garan es de valeur marchande ou d’adéqua on pour une finalité...
  • Page 93 RL75, RL94 et RLX94i de sa Série Luxury, si vous enregistrez votre chauffe-eau dans les 30 jours qui suivent son achat. Les produits non enregistrés resteront couverts par la garan e limitée standard de Rinnai telle que décrite dans le manuel d’instal- la on et d’u lisa on qui accompagne le produit.
  • Page 94 U307-0730 100000244(05) 7/2014...

This manual is also suitable for:

Rl94eRlx94iRl94iRl75e

Table of Contents