Toshiba RAV-SM2242DT-E Service Manual page 46

Split type indoor unit
Hide thumbs Also See for RAV-SM2242DT-E:
Table of Contents

Advertisement

[F02 error]
Is connection of TC sensor connector
(CN101 on Indoor P.C. board) correct?
YES
Are characteristics of
TC sensor resistance value normal?
YES
Check indoor P.C. board (MCC-1403).
Defect → Replace
[F01 error]
Is connection of TCJ sensor connector
(CN102 on Indoor P.C. board) correct?
YES
Are characteristics of
TCJ sensor resistance value normal?
YES
Check indoor P.C. board (MCC-1403).
Defect → Replace
NO
NO
∗ Refer to Charqacteristics-2.
NO
NO
∗ Refer to Charqacteristics-2.
Correct connection of connector.
Correct connection of connector.
– 46 –
Replace TC sensor.
Replace TCJ sensor.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rav-sm2242dt-trRav-sm2802dt-eRav-sm2802dt-tr

Table of Contents