Yamaha LSI YMF744B Technical Manual page 41

Table of Contents

Advertisement

YMF744B
F1h: Scan In/ Out Data
Read / Write
Default: 00h
b7
b6
b5
b[7:0] ..........SCAN DATA
This is the data port for reading and writing the internal state.
F2h: Current FM Synthesizer Index
Read Only
Default: 00h
b7
b6
b5
Current FM Synthesizer Index
b[7:0] ..........Current FM Synthesizer Index
This register indicates current index of the FM Synthesizer.
F3h: Current FM Synthesizer Array
Read Only
Default: 00h
b7
B6
b5
-
-
-
b0................CFA: Current FM Synthesizer Arary
This bit indicates that the FM Synthesizer array is being currently set to Array 0 or 1.
"0": Array 0
"1": Array 1
F4h: FM Synthesizer / MPU401 Status
Read Only
Default: 80h
b7
b6
b5
FFEMP FFFUL
-
b0................MPUS: MPU401 Status
This bit indicates current MPU401 status.
"0": Default mode (Intelligent mode)
"1": UART mode
b6................FFFUL: FM Synthesizer FIFO Full
This bit indicates whether or not FIFO followed by the FM Synthesizer is full.
"0": not Full
"1": Full
b4
b3
b2
b1
SCAN DATA
b4
b3
b2
b1
b4
b3
b2
b1
-
-
-
(default)
b4
b3
b2
b1
-
-
-
(default)
(default)
-41-
b0
b0
b0
-
CFA
b0
-
MPUS
February 3, 1999