damaged cable, replace it with a new one. Use
only genuine replacement cable.
9. Never carry the product by the cable.
10. Never pull on the cable to disconnect any of the plugs
11. Always wind cable carefully, avoiding kinking.
12. Use only on AC mains supply voltage shown on
the product rating label.
13. Our products are double insulated to EN60335.
Under no circumstance should an earth be
connected to any part of the product.
Preparation
1. While using your product always wear substantial
footwear and long trousers.
2. The use of eye protection is recommended.
3. The use of ear protection is recommended.
4. To prevent dust irritation, the wearing of a face
mask is recommended.
5. Do not wear loose clothing or jewellery that can be
drawn into the air inlet.
6. Do not wear clothing with attachments, i.e. toggles or
drawstrings that can be drawn into the air inlet.
7. Inspect your product before each use.
8. Do not use if any part is damaged or broken or if
any of the screws are loose. Have it repaired by
an authorised repairer.
9. Always check your product is in a safe operating
condition before use.
Use
1. Use the product only in daylight or good artificial
light.
2. Do not use the product when it is raining or in
damp and wet areas.
3. Never use the product in or near water or ponds.
4. Know how to stop the product quickly in an emergency.
5. On slopes, be extra careful of your footing and
wear non-slip footwear.
6. Do not walk backwards whilst operating your
CABLES
IMPORTANT
Use only 1.00mm
2
size cable up to 40 metres
length maximum.
Maximum rating :
1.00mm
2
size cable, 10 amps 250 volts AC.
YOUR PRODUCT IS SUPPLIED WITH CABLE
WIRED DIRECTLY INTO THE PRODUCT.
1. Flymo Mains Cables and Extension Cables are
available from your local Approved Service Cen-
tre.
2. Do not wire an extension cable directly to your
product yourself. Please contact your local
Approved Service Centre for further information on
the connectors and kits available.
3. Only use extension cables specifically designed
for outdoor use.
CONNECTORS
IMPORTANT
Flymo connectors are suitable for use with 2 core
cable only. Under no circumstances should these
connectors be used for earthed products.
All Flymo connectors and cables are of splashproof
construction. They are not waterproof and must not
be left outside permanently nor should they be
submerged or immersed in water. Do not let cable
lay or trail through pools of water or splashed with
water from hose pipes.
MAINS PLUG REPLACEMENT
IMPORTANT
If the plug supplied is cut off it should be de-
stroyed. There is an electric shock hazard if a
cut off plug is inserted into a 13 amp socket.
product, you could trip. Walk, never run.
7. Always direct the cable to the rear, away from the
product.
8. Keep children, pets and bystanders at a safe
distance when using your product.
9. Keep long hair away from air inlet.
10. Keep all inlets clear of debris.
11. Always remain alert.
12. Do not attempt to use your product without the
fully assembled debris bag fitted.
13. Never blow debris in the direction of bystanders.
14. Do not overreach. Keep proper footing and
balance at all times.
15. The impeller continues to rotate after your product
has been switched off.
16. Remove the plug from the mains :-
-
before removing or replacing fully assembled
debris bag;
-
before leaving the product unattended for any
period;
-
before clearing a blockage;
-
before checking, cleaning or working on the
product;
-
if the product starts to vibrate abnormally. Check
immediately. Excessive vibration can cause injury.
Maintenance and storage
1. Keep all nuts, bolts and screws tight to be sure the
product is in a safe working condition.
2. Replace worn or damaged parts for safety.
3. Use only genuine replacement parts and
accessories
4. Inspect the debris bag regularly. If the debris bag
becomes worn or damaged, replace.
4. Store in a cool dry place and out of reach of
children. Do not store outdoors.
1. No earth required. Flymo products are double
insulated to EN60335 and under no
circumstances should an earth be connected to
any part of the product.
2. Ensure the mains voltage suits your product
3. IMPORTANT!
The wires in the mains lead are coloured in
accordance with the following code:
BLUE
-
NEUTRAL
BROWN
-
LIVE
The wire which is coloured BLUE must be
connected to the Terminal which is marked with
the letter 'N' or coloured BLACK.
The wire which is coloured BROWN must be
connected to the Terminal which is marked with
the letter 'L' or coloured RED.
4. It is important that the outer sheath is clamped
correctly into the 3-pin plug.
5. If in doubt consult your local Service Repairer or
qualified electrician before the machine is used.
6. A 13 Amp fuse must be fitted to the Mains Plug.
7. The normal plug fuse and household fuse only
protect the electrical equipment and are not a
safeguard against electrocution.
If the mains cable is damaged, it must be
replaced with the correct Flymo assembly from
an Flymo Approved Service Dealer (see leaflet
enclosed in product)