Technical Data; Test Pieces; Detection Zone - Siemens SIMATIC FS600 Instruction Manual

Table of Contents

Advertisement

14

Technical data

14.1

Test Pieces

The following test pieces are defined for the purpose of controlling the effectiveness of
the monitoring function by the detection zones:
Cylinder, 500 mm in length, reflectance factor 1.8 % ± 0.2 %, for stationary
applications, diameter: 30, 40, 50, 70, 150 mm
Cylinder, 1000 mm in length, 200 mm in diameter, reflectance factor 1.8 % ± 0.2 %,
for mobile systems (e.g. AGV).
14.2

Detection zone

Detection range
at a resolution of 30 mm
at a resolution of 40 mm
at a resolution of 50 mm
at a resolution of 70 mm
at a resolution of 150 mm
Reflectance factor
Min. adjustable range
Detection range of test piece
from housing
Response time
Number of detection zones
Output
Safety category
Startup
Restart
Table 14.2-1:
SIMATIC FS620I
4.00 m
4.00 m
min. 1.8%
200 mm
min. 0 mm
min. 80 ms (2 scans)
adjust. up to 640 ms (16 scans)
4/8 (changeover via switch inputs)
2 failsafe PNP transistor outputs,
24 V / 250 mA
Requirement class 4 as per DIN V 19250, fail-safe,
category 3 as per EN 954-1,
Type 3 as per DIN EN 61496-1 and IEC 61496-3,
SIL 2 acc. to IEC 61508
The startup test and start interlock can be
adjusted separately.
Automatic or manual, adjustable from 160 ms to 10 s
Technical Data – Detection Zone