Regency F5100 Owners & Installation Manual page 2

Freestanding woodstove
Table of Contents

Advertisement

The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have
any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.
SAFETY NOTE: If this woodstove is not properly installed, a house fi re may result. For your safety, follow the installation
instructions, contact local building, fi re offi cials, or authority having jurisdiction about restrictions and installation inspection
requirements in your area.
The following statements are required by the Environmental Protection Agency:
"This manual describes the installation and operation of the Regency F 5100 catalytic equipped heater. This heater meets
the U.S. ENVIROMENTAL PROTECTION AGENCY's emission limits for wood heaters built on or after July 1 1990. Under
specifi c test conditions this heater has been shown to deliver heat at rates ranging from 11738 BTU/hr 41982 BTU/hr."
"This wood heater contains a catalytic combustor, which needs periodic inspection and replacement for proper operation. It
is against the law to operate this wood heater in a manner inconsistent with operating instructions in this manual, or if the
catalytic element is deactivated or removed."
CAUTION: BURN UNTREATED WOOD ONLY. OTHER MATERIALS SUCH AS WOOD PRESERVATIVES, METAL FOILS,
COAL, PLASTIC,GARBAGE, SULPHUR OR OIL MAY DAMAGE THE CATALYST
"This heater is designed to burn natural wood only. Higher effi ciencies and lower emissions generally result when burning
air dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods."
DO NOT BURN:
• Treated wood
• Coal
• Garbage
• Cardboard
• Solvents
• Colored Paper
• Trash
The authority having jurisdiction (such as Municipal Building Department, Fire Department, Fire Prevention Bu-
reau, etc.) should be consulted before installation to determine the need to obtain a permit.
Note: Due to the high effi ciency of the F5100 unit, This unit requires the use of double wall pipe from the stove top to
either wall or roof exit. A minimum of 36" vertical rise is required prior to using any elbows.
This unit must be connected to either a listed factory built chimney suitable for use with solid fuels and conforming to,
ULC629 in Canada or UL-103HT in the United States of America. or code approved masonry chimney with fl ue liner.
F5100 is tested and certifi ed to ULC-S627-00 and UL1482-2011.
SAVE THESE INSTRUCTIONS
2
Thank-you for purchasing a
REGENCY FIREPLACE PRODUCT.
Keep those REGENCY FIRES burning.
F5100 Video
F5100 Regency Freestanding Woodstove

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3500

Table of Contents