Natural Gas Conversion - Jenn-Air W10394706A User Manual

30" (76.2 cm), 36" (91.4 cm) and 48" (121.9 cm) commercial style gas cooktops
Table of Contents

Advertisement

Available languages

Available languages

1. Turn manual shutoff valve to the closed position.
A
A. To cooktop
B. Shutoff valve (closed position)
C. Gas supply line
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
1. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
2. Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the "LP" or "NAT" position. Turn over the spring
retainer so the "NAT" is showing on the bottom. Snap the
spring retainer back into the cap. Reinstall the cap onto the
regulator.
E
D
A. Access cap
B. Gasket
C. Gas pressure regulator
3. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm)
water column above the set pressure. The inlet pressure to
the regulator should be as follows for operation and checking
the regulator setting:
Natural Gas:
Minimum pressure: 6" (15.2 cm) WCP
Maximum pressure: 14" (35.5 cm) WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
1" water column pressure above the manifold pressure
shown on the model/serial rating plate.
Line pressure testing above ½ psi gauge (14" WCP)
The cooktop and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).

Natural Gas Conversion

B
C
A
B
C
D. NAT position
E. LP position
To Convert Surface Burners
1. If installed, remove the burner grates.
2. Remove burner cap.
3. Remove the burner base.
A
B
C
A
B
4. Apply masking tape to the end of a
hold the gas orifice spud in the nut driver while changing it.
Insert nut driver into gas opening and press down onto the
gas orifice spud and remove by turning the gas orifice spud
counterclockwise and lifting out. Set gas orifice spud aside.
5. Replace with correct Natural gas orifice spud. See the
"Natural Gas Orifice Spud/Hood Chart."
Burner orifice spud
A. Size stamp or color
Use the following chart to find the exact orifice spud
placement.
Remove choke from medium burner base.
Natural Gas Orifice Spud/Hood Chart
Burner Rating
Size
5,000 BTU
1.01 mm
15,000 BTU
1.75 mm
20,000 BTU
2.10 mm
0.52 mm
6. Place LP gas orifice spuds in plastic parts bag for future use
and keep with package containing literature.
7. Replace the burner base.
8. Replace burner cap.
9. Repeat steps 2 through 8 for the remaining burners.
Large Dual Burner
A. Burner cap
B. Burner base
Medium Burner
A
A. Burner cap
B
B. Burner base
C. Choke (for use with medium
burner, LP gas only)
Small Burner
A. Burner cap
B. Burner base
mm nut driver to help
A
Burner Style
Small burners
Medium burners
Large burner - main
Large burner - simmer
13