Lp gas and high altitude conversion
Hide thumbs Also See for JGC1530B Series:
Table of Contents

Advertisement

Available languages

Available languages

Tools and Parts

Gather the required tools and parts necessary for correct LP gas
conversion.
Tools needed
Flat-blade screwdriver
³⁄₃₂" (#0 [2.0 mm]) flat-blade screwdriver (screwdriver shaft
must be a minimum of 2½" [6.4 cm] long)
Adjustable wrench
7.0 mm nut driver
7.0 mm wrench
Parts supplied
LP orifice package (W10686634)
Conversion label (W10590570)
High Altitude Conversion
To convert the cooktop for elevations above 6,560 ft (1999.5 m),
order a High Altitude Conversion Kit.
Part Number W10686630 - LP high altitude
Part Number W10686629 - Natural gas high altitude
To order, see the "Assistance or Service" section of the Use and
Care Guide.
IMPORTANT: Gas conversions from Natural gas to LP gas must
be done by a qualified installer. Before proceeding with
conversion, shut off the gas supply to the cooktop prior to
disconnecting the electrical power.
WARNING
This conversion kit shall be installed by a
qualified service agency in accordance
with the manufacturer's instructions and
all applicable codes and requirements of
the authority having jurisdiction. If the
information in these instructions is not
followed exactly, a fire, explosion or
production of carbon monoxide may
result causing property damage, personal
injury or loss of life. The qualified service
agency is responsible for the proper
installation of this kit. The installation is
not proper and complete until the
operation of the converted appliance is
checked as specified in the
manufacturer's instructions supplied with
this kit.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Convert from Natural Gas to LP
1. Turn manual shutoff valve to the closed position.
A
A. To cooktop
B. Shutoff valve (closed position)
C. Gas supply line
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
A
A. Access cap
B. Rear of cooktop
Gas
B
C
B
C
D
C. Gas pressure regulator
D. Gas flow
3