Sunline 2000Tm Heat Pump; Ratings; Indoor Sound Power Ratings - York BQ240 Technical Manual

Sunline 2000 single package air-to-air heat pumps 20 nominal tons, 8.8 eer
Hide thumbs Also See for BQ240:
Table of Contents

Advertisement

ECONOMIZER HOOD
2" DISPOSABLE
FILTERS
OUTDOOR AIR OPENING
FOR INTERNAL ECONOMIZER
SIDE AND BOTTOM
SUPPLY & RETURN AIR
FIGURE 1 :
SUNLINE 2000
TABLE 1: RATINGS
1
COOLING CAPACITY
80//67-95º F
MODEL
MBH
EER
IPLV MBH COP MBH COP
BQ240
222
8.5
7.5
1. Certified in accordance with the Unitary Large Equipment Certifi-
cation Program which is based on ARI Standard 340/360.
2. Models with electric heat have single point power supply.
EER = Energy Efficiency Ratio at full load - the cooling capacity in BTU's per hour
(Btuh) divided by the power input expressed in BTUH per watt (Btuh/watt).
TABLE 2: INDOOR SOUND POWER RATINGS
ESP
Unit
CFM
Size
IWG
RPM
BQ240
8,000
1.00
1,020
1. At a distance of 10 ft. from the blower.
NOTE: These values have been derived using a model of sound propagation, measuring the indoor ambient sound levels ten feet from the source.
The dBA values provided are for reference only. Calculation for dBA values cover matters of system design and application. This constitutes
an exception to any specification or guarantee requiring a dBA value or sound data in any other form than sound power level ratings.
14
LONG LASTING POWDER PAINT FINISH
NPT FEMALE
CONDENSATE DRAIN
FULL PERIMTER 14 GUAGE BASE
RAILS WITH LIFTING HOLES
HEAT PUMP
TM
ELECTRIC
1
HEATING CAPACITY
HEAT
NOM.
47º F
17º F
CAPACITY
(KW)
KW
226
3.0
120
2.0
18,36,54,72
Blower
Octave B and Centerline Frequency (Hz)
BHP
63
125
250
6.65
102
102
92
HIGH EFFICIENCY COMPRESSORS
WITH CRANKCASE HEATERS
COPPER TUBE/ALUMINUM FIN
OUTDOOR COILS
ELECTRIC HEATER LOCATION
(OPTION)
BELT-DRIVE
BLOWER MOTOR
COP = Coefficient of Performance - the total heating capacity provided by the refrig-
eration system, including circulating fan heat, but excluding supplementary resis-
tance (Btu's per hour) divided by the total electric input (watts) x 3.412.
IPLV = Integrated part load value. The EER of the unit operating on first stage only.
2
HEAT PUMP WITH ELECTRIC HEAT
MODEL
BQ240E18
BQ240E36
BQ240E54
BQ240E72
Sound Power (db 10
500
1,000
2,000
4,000
85
87
80
75
036-21489-001-C-1004
LOW VOLTAGE RELAY BOARD
AND TERMINAL STRIP
ELECTRICAL DISCONNECT
MOUNTING LOCATION
(Field Installed)
KNOCKOUT FOR
SIDE CONTROL WIRING AND
SIDE POWER WIRING ENTRY
TERMINAL BLOCK
(For Single Point Power Supply
With Electirc Heat)
BOTTOM & CONTROL
WIRING ENTRY
MBH
EER
222
8.5
222
8.5
220
8.5
218
8.5
-12
Watts)
db(A)@ 10 Ft.
SWL db(A)
8,000
70
92
Unitary Products Group
IPLV
7.5
7.5
7.4
7.4
1
59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sunline 2000

Table of Contents