Operating Manual - nX, nXe, and nXp Power Amplifiers
3) Use an Ashly WR-5 or neWR-5 remote control.
4) Use the event scheduler.
Note: A full preset recall event will overwrite any unsaved changes, so be sure the current configuration is saved before
continuing or any changes will be lost. The amplifier always loads the last working settings on power-up, to preserve any changes
should the power be inadvertently turned off prior to saving a preset. Caution: A new preset may have dramatically different
settings capable of damaging sound system components, so be careful not to recall the wrong preset while the system is on.

9.4 Device Control Tabs

The following device control tabs are available for each amplifier. The tabs include Control Surface, Security, Network
Properties, DSP, Input Source, Meters, Meter Dynamics, Meters AutoLeveler, Metering, Event Scheduler, and Fault Log.
9.4a Software Control Surface - Global
The control surface is the main user interface for the
amplifier section. DSP functions, if available, are managed from
the DSP tab. The following amplifier functions are available in
the control panel:
Name
- The user defined name for this specific
amplifier. Up to 20 characters can be used.
Model
- The model of amplifier being addressed
Power
- Shows power status as On, Off, or Standby.
Power On/Standby
also be controlled by a rear panel contact closure or by the
Front Panel Enable/Disable
all level controls at maximum (fully on) regardless of their position. Note that the software attenuators shown on the control surface
will always reflect the physical position of the amplifier's front panel attenuators, even when they are disabled and not attenuating the signal.
Remote Attenuator Enable/Disable
Protect - Channel Thermal
allowed. At 90% of maximum, attenuation is applied to the overheating channel. (see
Protect - Channel Average Power
over-power output condition. (see
Protect - Channel Rail Fault
undervoltage condition on the output DC power supply voltage rails. They are
outside of their specified tolerance range. (see
Internal Amplifier Ambient
DIP Switch Settings
for setting HPF, Limiter, Gain, and Output Mode. All current DIP switch positions
and parameters are displayed here on the software control surface.
20
- This shows power status and allows the user to set power to standby from software. Standby can
event
- This disables both the front panel power switch and all level controls, fixing the value of
- Disables all "Remote DC Level Control" Euroblock connectors on back panel
- This tracks the front panel
- This shows that the amplifier has automatically attenuated signal to prevent an
section 3
or
section
14)
- This means there is an overvoltage or
section 3
- This indicates the internal temperature.
- Each channel has a six position rear-panel DIP switch
9.4a - Control Surface Global Functions
scheduler. The front panel power switch blinks when in standby.
TEMP
LED, lit when amp temperature is 80% of maximum
or
section
14)
section 3
or
section
14)
9.4a - DIP Switch Settings