INSTALLATION OF KIT PARTS
12.
STANDARD KIT PARTS
Battery Tray Kit (CXS type)
1.
Install the battery guard pipe on the frame.
Set the battery tray on the battery guard pipe and tighten the bolts.
2.
Route the starter cable under the tank and connect it to the starter
solenoid.
3.
Connect the battery ground cable to the generator rear housing.
4.
Set the battery on the battery tray and secure with the battery set
bolt.
Connect the starter cable to the battery positive ( ) terminal first,
then to the negative ( ) terminal. When disconnecting, disconnect
at the battery negative ( ) terminal first.
5.
Install the battery guard plate on the battery guard pipe.