Gree R410A Service Manual page 13

Super free match series t1/r410a/50hz
Hide thumbs Also See for R410A:
Table of Contents

Advertisement

U-cool
Model
Cooling
Capacity
Heating
Power supply
Motor power input
Air flow volume
Sound pressure level
(SH/H/MH/M/ML/L/SL)
Output
Fan motor
Running
current
Gas
Connecting
Liquid
pipe
Connection method
External dia.
Drain pipe
Thickness
Outline
W×D×H
dimension
Package
W×D×H
dimension
Net Weight/ Gross weight
Loading quantity
Notes:
a. The rated cooling capacity data is measured under the following work condition: Indoor Temperature is 27℃
DB, 19℃WB. Outdoor Temperature is 35℃DB. The rated heating capacity data is measured under the following
work condition: Indoor Temperature is 20℃DB. Outdoor Temperature is 7℃DB, 6℃WB.
b. The data will change with the change of products. Refer to those parameters listed on nameplate.
c. Noise was tested in semi-silenced room, so the actual noise value will be a little higher for change of ambient.
GWH(07)UA-K
3DNA1B/I
kW
2.1
kW
2.6
V-Ph-Hz
220~240-1-50
kW
0.03
m3/h
450
CFM
265
37/35/32/30/28/
dB(A)
26/24
kW
0.01
A
0.136
inch
3/8"(Φ9.52mm)
inch
1/4"(Φ6.35mm)
Flare
Connection
mm
Φ20
mm
1.5
mm
860×153×299
mm
944×247×386
kg
9.5/12.5
20'GP
324
40' GP
666
40' HQ
740
GWH(09)UA-K
GWH(12)UB-K
3DNA1B/I
3DNA1B/I
2.6
3.5
2.8
3.8
220~240-1-50
220~240-1-50
0.03
0.04
450
560
265
330
38/35/32/30/28/
39/37/34/31/29/
26/25
27/26
0.01
0.02
0.136
0.2
3/8"(Φ9.52mm)
3/8"(Φ9.52mm)
1/4"(Φ6.35mm)
1/4"(Φ6.35mm)
Flare
Flare
Connection
Connection
Φ20
Φ20
1.5
1.5
860×153×299
896×159×320
944×247×386
973×255×403
9.5/12.5
10/13
324
279
666
585
740
650
Super Free Match
Service Manual
GWH(18)UC-K
3DNA1B/I
5.3
5.8
220~240-1-50
0.06
850
500
44/40/37/35/33/
31/28
0.025
0.31
1/2"(Φ12.7mm)
1/4"(Φ6.35mm)
Flare
Connection
Φ20
1.5
998×178×340
1083×283×428
14.0/17.0
216
440
495
9
PRODUCT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents